Final | 5/5/2005 | 5/6/2005 | 5/6/2005 | A | PASS |
Jack Frank
|
|
|
david; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok 5/6/2005 2:42:31 PM
|
DOC - Permit Finaled | 5/6/2005 | 5/6/2005 | 5/6/2005 | P | PASS |
Jack Frank
|
|
|
Finaled by inspector at 5/6/2005 2:42:35 PM
|
Final | 5/5/2005 | 5/5/2005 | 5/5/2005 | P | FAIL |
Bob Reichert
|
|
|
david; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called contr, left corr notice, 352.30(A) rnc shall be supported within 3' of box (service riser), 314.29 Access shall be provided to jetted tub, 406.5 Cover shall seat against surface for front recpt, kitchen closet switch and light shall be provided,master bath fixture shall be installed, switched outlet to left of fireplace shall turn on, recpt cover at jetted tub shall be provided 5/5/2005 4:44:10 PM
|
Electrical Rough-In | 3/16/2005 | 3/17/2005 | 3/17/2005 | A | FAIL |
Jack Frank
|
|
|
david; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cor. posted calle box fill 2 gang bottom stairs, all recepts in din rm on kit circuit 3/17/2005 9:19:23 AM
|
Rough-In Permanent Service | 3/17/2005 | 3/17/2005 | 3/17/2005 | P | PASS |
Jack Frank
|
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Barbara Moore r/i ok
p/s u/g new ok 3/17/2005 1:01:40 PM
|
Electrical Rough-In | 3/15/2005 | 3/16/2005 | 3/16/2005 | A | FAIL |
Jack Frank
|
|
|
Dave; Phone #: ###-#### Internet Inspection Request from: Jan Rice called no address could not locate, also no street sign 3/16/2005 9:54:11 AM
|
Application received | | | 3/15/2005 | | |
|
|
|
|
Issue permit | | | 3/15/2005 | | DONE |
|
|
|
|