Permit Information
Permit NumberELE05-01154
StatusFinaled
Name POWER PLUS INC
Site Address 1801 W WASHINGTON ST
Project Name 
Customer Number14639
ePlanReview 
Description
Electrical Permit - Repair: hook-up water heater & furnace
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/11/20054/12/20054/12/2005APASS
DetailsPat Lass
please contact Miles, thank you.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
DOC - Permit Finaled4/12/20054/12/20054/12/2005APASS
DetailsPat Lass
Finaled by inspector at 4/12/2005 9:47:19 AM
Final4/6/20054/7/20054/7/2005AFAIL
DetailsPat Lass
ready for final, please contact Mike Johnson, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
422.31 Disconnection of Permanently Connected Appliances.
(A) Rated at Not Over 300 Volt-Amperes or 1/8 Horsepower. For permanently connected appliances rated at not over 300 volt-amperes or 1 /8 hp, the branch-circuit overcurrent device shall be permitted to serve as the disconnecting means.
(B) Appliances Rated Over 300 Volt-Amperes or 1/8 Horsepower. For permanently connected appliances rated over 300 volt-amperes or 1/8 hp, the branch-circuit switch or circuit breaker shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from the appliance or is capable of being locked in the open position.
358.30 Securing and Supporting.
EMT shall be installed as a complete system as provided in Article 300 and shall be securely fastened in place and supported

300.15 Boxes, Conduit Bodies, or Fittings - Where Required.
Where the wiring method is conduit, tubing, Type AC cable, Type MC cable, Type MI cable, nonmetallic-sheathed cable, or other cables, a box or conduit body complying with Article 314 shall be installed at each conductor splice point, outlet point, switch point, junction point, termination point, or pull point, unless otherwise permitted in 300.15(A) through (M).
210.70 Lighting Outlets Required.
Lighting outlets shall be installed where specified in 210.70(A), (B), and (C).
(3) Storage or Equipment Spaces.

210.63 Heating, Air-Conditioning, and Refrigeration Equipment Outlet.
A 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be installed at an accessible location for the servicing of heating, air-conditioning, and refrigeration equipment. The receptacle shall be located on the same level and within 7.5 m (25 ft) of the heating, air-conditioning, and refrigeration equipment. The receptacle outlet shall not be connected to the load side of the equipment disconnecting means.


In-use cover is upside down.
4/7/2005 10:16:46 AM
Application received  4/6/2005  
This permit was created on the web by Wendy Waters