Final | 5/10/2006 | 5/10/2006 | 5/10/2006 | A | PASS |
Pat Lass
|
|
|
###-#### Internet Inspection Request from: Bob Glenn
|
Final | 5/8/2006 | 5/8/2006 | 5/8/2006 | A | FAIL |
Pat Lass
|
|
|
###-#### Internet Inspection Request from: Bob Glenn 210.52 Dwelling Unit Receptacle Outlets. (5) Receptacle Outlet Location. Receptacle outlets shall be located above, but not more than 500 mm (20 in.) above, the countertop.
314.20 In Wall or Ceiling. In walls and ceilings constructed of wood or other combustible surface material, boxes shall be flush with the finished surface or project therefrom. this is on the first floor.
|
Rough-In Permanent Service | 1/16/2006 | 1/17/2006 | 1/17/2006 | A | PASS |
William E Thomas
|
|
|
###-#### Internet Inspection Request from: Bob Glenn ri ok p/s u/g n ok
|
Electrical Rough-In | 10/3/2005 | 10/4/2005 | 10/4/2005 | A | PART |
Pat Lass
|
|
|
michael///conduit inspection please; Phone #: ###-#### Internet Inspection Request from: Barbara Moore U/G Ok
|
Electrical Rough-In | 10/3/2005 | 10/4/2005 | 10/3/2005 | A | CANC |
Jim Schmer
|
|
|
michael///conduit inspection please; Phone #: ###-#### Internet Inspection Request from: Barbara Moore put into computer twice
|
Application received | | | 9/27/2005 | | DONE |
|
|
|
This permit was created on the web by Bob Glenn
|