Final | 1/26/2006 | 1/26/2006 | 1/26/2006 | P | PASS |
Jack Frank
|
|
|
stephen - ###-#### after 2:00
|
Stop Work/Reinspection Fee | 1/25/2006 | 1/25/2006 | 1/26/2006 | A | DONE |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/24/2006 at 1:05:06 PM. Contact: ###-####. fee due again violations not corrected and more created
|
Final | 1/24/2006 | 1/25/2006 | 1/25/2006 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/24/2006 at 1:05:06 PM. Contact: ###-####. fee due and new correction notice posted called left massage violations not corrected new one created 200.6 shall not ID #6 or smaller neutral green identified as white,
|
Final | 1/24/2006 | 1/24/2006 | 1/24/2006 | A | NH |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/24/2006 at 7:09:15 AM. notice posted called
|
Final | 1/19/2006 | 1/20/2006 | 1/20/2006 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/19/2006 at 3:36:56 PM. Contact: ###-####. cor. fee due posted called 314.17 needs connectors at bell boxes for cables, 225.30 detached garage shall have only one branch circuit or feeder, 225.31,32 provide disconnect at required location
|
Stop Work/Reinspection Fee | 1/20/2006 | 1/20/2006 | 1/20/2006 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/19/2006 at 3:36:56 PM. Contact: ###-####. reinspection fee due, and posted called
|
Rough-In Permanent Service | 11/10/2005 | 11/14/2005 | 11/14/2005 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 11/10/2005 at 1:54:41 PM. Contact: ###-####. r/i ok p/s u/g new ok
|
Rough-In Permanent Service | 11/9/2005 | 11/10/2005 | 11/10/2005 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 11/9/2005 at 5:22:56 PM. Contact: ###-####. cor. called left message all violations not corrected 300.4 nail plates and 11/4" reinspection fee due
|
Stop Work/Reinspection Fee | 11/10/2005 | 11/10/2005 | 11/10/2005 | A | DONE |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 11/9/2005 at 5:22:56 PM. Contact: ###-####. reinspection fee due posted corrections not made 300.4 nail plates and 11/4" called left message
|
Rough-In Permanent Service | 11/7/2005 | 11/9/2005 | 11/9/2005 | P | FAIL |
Jack Frank
|
|
|
steve ###-#### cor. called left message 300.4 nail plates, 11/4" inside outside of framing members, 312.5 conn for grd wire at p/s, uncover u/g from house to garage install outside front recept box do not cover posted
|
Issue permit | | | 11/7/2005 | | DONE |
|
|
|
|
Application received | | | 11/7/2005 | | |
|
|
|
|