Permit Information
Permit NumberELE05-04290
StatusExpired
Name MAINLINE ELECTRICAL
Site Address 8660 W EMERALD ST Unit: 152
Project NameEMERALD WEST PLAZA
Customer Number 
ePlanReview 
Description
TI rewiring outlets and lights per initial cert of value $3,200///11/29/05 LEG
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Telephone call  12/12/2012 DONE
DetailsChristina Prado
Per Bob A & Doug P - ok to pay 1hr admin fee to reopen permit for final inspection. New ELE permit is required to be pulled with new contractor and finaled prior to BLD final. ELE permit fee is to be $46.31
DOC - Permit Expired12/22/201112/22/201112/22/2011APASS
DetailsJack Frank
note new contr will secure permit correct all violations and finish job then request final inspection when all that is completed
Final10/6/201110/6/201110/6/2011PCANC
DetailsJack Frank
junior - please call 1/2 hr prior Phone #: ###-#### called new contr he is checking out job , and will escure permit for the work he does
Change Status to I  10/6/2011 DONE
re-open for final inspection
ELE-Aging Inspection9/23/20119/23/20119/23/2011 DONE
DetailsJack Frank
see added doc expire, and notes
DOC - Permit Expired9/23/20119/23/20119/23/2011APASS
DetailsJack Frank
talked with owner told them they need to hire ele. contr., he will secure permit and take over job, and correct all violations 370 had noted
Final6/24/20116/29/20116/29/2011PFAIL
DetailsJack Frank
Jayne Blazek (tenant), work was already done a long time ago, just never scheduled inspection. Phone #: ###-#### already talked with Jayne, there are supposed to hire electrical contractor to take over job and finish what 1st contractor did not finish see failed final inspection request by Bob
Final5/23/20115/26/20115/26/2011PNR
DetailsJack Frank
Jane Phone #: ###-#### talked with owner they will hire new contractor to take over work
CHANGE STATUS TO I  5/23/2011 DONE
DetailsBarbara Stitt
Re-open for final per Bob Archibald 5-23-11
Case Summary (ELE)  5/23/2011 DONE
Miscellaneous action  5/20/2011 PEND
DetailsBob Archibald
Electrical contractor may reactivate for final inspection. 1 hour admin. fee required. Bob A.
ELE-Aging Inspection4/24/20074/24/20074/26/2007 PART
DetailsJack Frank
talked with contractor told him permit will be expired his never called back or did anything
DOC - Permit Expired4/26/20074/26/20074/26/2007APASS
DetailsJack Frank
ELE-Aging Inspection2/22/20072/22/20072/26/2007 PART
DetailsJack Frank
called talked with contractor hr will check out status of job
ELE-Aging Inspection12/14/200612/14/200612/15/2006 PART
DetailsJack Frank
ELE-Aging Inspection10/5/200610/5/200610/5/2006 NR
DetailsBob Reichert
not ready yet
ELE-Aging Inspection8/4/20068/4/20068/7/2006 NR
DetailsBob Reichert
talked to elect and struct, waiting for contr to call
ELE-Aging Inspection5/31/20065/31/20066/2/2006 DONE
DetailsBob Reichert
called contr, still not ready for final, open corr notice
Final3/28/20063/28/20063/28/2006PFAIL
DetailsBob Reichert
Robert -- location back of office; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called contr, set up meeting when he calls back in, 314.23(C) enclosure mounted in finished surface shall be rigidly secured, BCC ceiling cover not approved
ELE-Aging Inspection3/22/20063/22/20063/22/2006 DONE
DetailsBob Reichert
called contr to set up inspection, left message
Electrical Rough-In12/7/200512/7/200512/7/2005PPASS
DetailsBob Reichert
robert; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections made, ric walls only ok
Electrical Rough-In12/6/200512/6/200512/6/2005PFAIL
DetailsBob Reichert
robert; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr not complete
Electrical Rough-In12/1/200512/1/200512/1/2005PFAIL
DetailsBob Reichert
robert --call 1st before insp for access; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr, left corr notice, 358.30 emt shall be securely fastened within 3' of panel,330.17 mc cable shall be protected in accordance with 300.4(A)&(D) where installed through or parallel to framing members,300.4 mc cable subject to physical damage shall be protected, i.e. cable shall not be run inside valley of 2x4 studs, 110.26(F)(1)(b) there shall be no foreign piping above dedicated space unless protection is provided.
Application received  11/29/2005  
Issue PAID IN FULL permit  11/29/2005 DONE