ELE-Aging Inspection | 3/4/2008 | 3/4/2008 | 3/6/2008 | | DONE |
Bob Reichert
|
|
|
no work being done, see doc expire
|
DOC - Permit Expired | 3/6/2008 | 3/6/2008 | 3/6/2008 | A | PASS |
Bob Reichert
|
|
|
see aging, no work being done
|
ELE-Aging Inspection | 1/3/2008 | 1/3/2008 | 1/11/2008 | | DONE |
Bob Reichert
|
|
|
may need to wait till spring for access
|
ELE-Aging Inspection | 10/10/2007 | 10/10/2007 | 10/16/2007 | | DONE |
Bob Reichert
|
|
|
called, left message to call to set up final
|
ELE-Aging Inspection | 1/19/2007 | 1/19/2007 | 1/19/2007 | | DONE |
Bob Reichert
|
|
|
called to set up request for final injspection
|
ELE-Aging Inspection | 10/2/2006 | 10/2/2006 | 10/2/2006 | | PART |
Jack Frank
|
|
|
called
|
ELE-Aging Inspection | 4/4/2006 | 4/4/2006 | 4/4/2006 | | PART |
Jack Frank
|
|
|
called contractor he will check status, and schedule final
|
Rough-In Permanent Service | 1/24/2006 | 1/24/2006 | 1/24/2006 | P | PASS |
Jack Frank
|
|
|
Mike (A M E Electric office ###-####) -- Jack Frank scheduled to meet at 12 pm (noon) -- call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong r/i ok check grds for other system and electrodes at final p/s o/h rec. ok
|
Conference | 1/23/2006 | 1/24/2006 | 1/24/2006 | A | NH |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/23/2006 at 5:04:02 PM. Contact: ###-####. notice posted called
|
Rough-In Permanent Service | 1/23/2006 | 1/24/2006 | 1/24/2006 | A | NH |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/23/2006 at 5:03:15 PM. Contact: ###-####. notice posted called
|
Rough-In Permanent Service | 1/20/2006 | 1/20/2006 | 1/20/2006 | P | FAIL |
Jack Frank
|
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong cor. fee due posted called more violations created from 1st correction posted, 250.102(C) shall size bond jumper to 250.66, 408.36(F) back fed device clip 120/230 V panel, 300.4 (F) bushings for 4 and larger, 300.10 tighten grd choke fittings, nipples from LBs shall have locknuts both sides of cabinet and be made up tight, everything is loose, 110.12(A) seal all unused KOs
|
Stop Work/Reinspection Fee | 1/20/2006 | 1/20/2006 | 1/20/2006 | P | PASS |
Jack Frank
|
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong reinspection fee due posted
|
Conference | 1/16/2006 | 1/16/2006 | 1/17/2006 | P | DONE |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 8:16:15 AM. Contact: ###-####.
|
Rough-In Permanent Service | 1/16/2006 | 1/16/2006 | 1/17/2006 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 1/16/2006 at 8:15:27 AM. Contact: ###-####. cor. called 314.28(A)(3) LBs too small, 200.6 shall not ID 6 or smaller neutral, 250.53,56 needs 2 grd rods, 250.24(A)(1) all GEC shall terminate at neutral bus, 250.90,92 shall bond nipples line side of p/s also bond both ends of GEC in pipe
|
Application received | | | 12/6/2005 | | |
|
|
|
|
Issue permit | | | 12/6/2005 | | DONE |
|
|
|
|