Final | 4/20/2006 | 4/20/2006 | 4/20/2006 | P | PASS |
Jack Frank
|
|
|
House is open and garage code is 6530.; Phone #: ###-#### Internet Inspection Request from: TJ Sturges ok
|
Final | 4/19/2006 | 4/20/2006 | 4/20/2006 | A | NH |
Jack Frank
|
|
|
re-inspection; Phone #: ###-#### Internet Inspection Request from: TJ Sturges notice posted called left message
|
Final | 4/17/2006 | 4/18/2006 | 4/18/2006 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: TJ Sturges corr. met electrician, 314.16 , box fill 314.17 conn for wiremold boxes island, counter also needs outlet island counter if other section is fixed to it, 210.52(C) (5) outlets shall not be over 20" above countertop by sink, also needs shelves installed in MB closet for clearence can be checked
|
Rough-In Permanent Service | 2/3/2006 | 2/3/2006 | 2/3/2006 | P | PASS |
Jack Frank
|
|
|
Please call Steve on your way to job site ###-#### he needs to meet you. r/i ok house has unfinished basement, p/s o/h new ok
|
Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 | A | NR |
Jack Frank
|
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called
|
Electrical Rough-In | 1/26/2006 | 1/26/2006 | 1/26/2006 | P | NR |
Mike Kinnear
|
|
|
please call when en route//steve; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa t/w general contractor they have adding window opener controlls that have not been wired at this time.
|
Rough-In Permanent Service | 1/25/2006 | 1/25/2006 | 1/25/2006 | P | FAIL |
Bob Reichert
|
|
|
###-#### Nicole or call 8503670 Cody; Phone #: ###-#### Internet Inspection Request from: Nicole Richardson called contr, left corr notice, 314.16 boxes shall be of sufficient size to provide free space for conductors, 300.4(A) & (D) nm cable and edge of holes shall be 1 1/4" from edge of framing member, 725.55 class 2&3 cable shall be separated from power or class 1 circuits, BCC all make-up shall be done, NOTE: 210.52, floor boxes not set, shall maintain spacing at final
|
Application received | | | 1/25/2006 | | DONE |
|
|
|
This permit was created on the web by Nicole Richardson
|