Rough-In Permanent Service | 3/17/2006 | 3/17/2006 | 3/17/2006 | P | PASS |
Bob Reichert
|
|
|
Brandon -- reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong corr made, ric ok
|
Rough-In Permanent Service | 3/9/2006 | 3/10/2006 | 3/10/2006 | P | FAIL |
Bob Reichert
|
|
|
Brandon; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong met owner, left corr notice,300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A) (1) receptacles shall be spaced so that no point is over 6' from a recpt horizontally along the floor line,334.30 nm cable shall be stapled within 8" of box, Note, smoke detector will be required in bedroom
|
Application received | | | 3/8/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 3/8/2006 | | DONE |
|
|
|
|