Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE06-01049
StatusFinaled
Name ROMAR ELECTRIC
Site Address 12251 W USTICK RD
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: additional wiring for church
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice ELE7/6/20067/6/20067/7/2006 DONE
This permit finaled on the web by Jeff Radford
First Notice5/30/20065/30/20067/6/2006 DONE
DetailsBob Reichert
Final5/30/20065/30/20065/30/2006PPASS
DetailsBob Reichert
please call Mike Dale with any questions; Phone #: ###-#### Internet Inspection Request from: Jeff Radford called left message about 1 recpt plate and outside light not working, ok to final
Final5/22/20065/22/20065/22/2006PNH
DetailsBob Reichert
ANY QUESTIONS PLEASE CALL MIKE DALE; Phone #: ###-#### Internet Inspection Request from: Jeff Radford locked, called contr and said to call when accessible
Final4/5/20064/5/20064/5/2006PCANC
DetailsBob Reichert
any questions please call Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford see ri
Electrical Rough-In4/5/20064/5/20064/5/2006PPASS
DetailsBob Reichert
any questions please call Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford corrections made, ric ok main level only
Electrical Rough-In4/3/20064/3/20064/3/2006PFAIL
DetailsBob Reichert
any questions please call Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford corrections not complete, called contr, will fix and recall
Electrical Rough-In3/28/20063/28/20063/28/2006PFAIL
DetailsBob Reichert
any questions please call Mike Dale; Phone #: ###-#### Internet Inspection Request from: Jeff Radford called, left message, left corr notice, 334.30 nm cable shall be stapled within 12" of boxes, 300.4(D) nm cable shall be 1 1/4" from edge of framing member, 210.70(2)(b) lighting outlet shall be switched and installed on exterior side of outdoor entrances or exits with grade level access, BCC no violations shall be retained, could not check attic, verify heater listing and load (wiring quite hot)
Owner Supplied Equipment  3/28/2006  
Application received  3/28/2006 DONE
This permit was created on the web by Jeff Radford