Final | 6/28/2006 | 6/28/2006 | 6/28/2006 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 6/28/2006 at 6:40:26 AM. Contact: ###-####. ok
|
Final | 6/27/2006 | 6/27/2006 | 6/27/2006 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 6/27/2006 at 7:17:56 AM. Contact: ###-####. corr. called 314.16 box fill island counter outlets, open grd bath rm outlets
|
Electrical Rough-In | 4/13/2006 | 4/14/2006 | 4/14/2006 | A | PASS |
William E Thomas
|
|
|
Scheduled by a contractor via Hello! on 4/13/2006 at 5:34:16 PM. Contact: ###-####. ri ok
|
Conference | 4/12/2006 | 4/13/2006 | 4/13/2006 | A | DONE |
Jack Frank
|
|
|
###-#### - greg went over corrections with contractor
|
Electrical Rough-In | 4/12/2006 | 4/12/2006 | 4/12/2006 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 4/12/2006 at 7:47:21 AM. Contact: ###-####. corr. called 250.148 splice all eqiup grd in boxes,300.4 (A)(1)&(D) nail plates 11/4", 314.43 no screws or nails in plastic boxes, 314.17 replace all boxes with broken internal clamps,314.27(C) use listed floor box fam rm314.20 outside boxes shall be flush, 334.30&314.17(C) staple romex 12" or 8" of fixtures and boxes, 300.14 6" free length, 110.3(A) replace damaged box in fam rm by kit. upgrade permit for 7rms
|
Application received | | | 4/4/2006 | | |
|
|
|
|
Issue & PRINT permit | | | 4/4/2006 | | |
|
|
|
|