Final | 7/27/2006 | 7/27/2006 | 7/27/2006 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla ok to final
|
Rough-In Permanent Service | 4/17/2006 | 4/17/2006 | 4/17/2006 | P | PASS |
Bob Reichert
|
|
|
Re-Inspection of rough electrical Internet Inspection Request from: Cevyn Recla corr made, ric ok, p/s u/g n ok
|
Rough-In Permanent Service | 4/14/2006 | 4/14/2006 | 4/14/2006 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called contr, left corr notice, 250.86 metal enclosures shall be grounded, 314.20 Boxes in walls constructed of combustible material shall be flush with finished surface, 210.52(A) recepts shall be installed in wall space such that no point is more than 6' from an outlet, 334.80 nm cable shall be derated if 2 or more cables in hole to be draft stopped,BCC there shall be an approved set of plans on job,and all make-up shall be done
|
Application received | | | 4/5/2006 | | DONE |
|
|
|