Final | 5/18/2006 | 5/19/2006 | 5/19/2006 | A | FAIL |
Bob Reichert
|
|
|
Greg; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt met owner, said to add 3 recpts for walls in bedrooms and to complete panel schedule, said wall in utility room should not need another recpt
|
Final | 5/17/2006 | 5/18/2006 | 5/18/2006 | A | FAIL |
William E Thomas
|
|
|
charles - ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 1. wall spacing is still not correct.
|
Final | 5/12/2006 | 5/12/2006 | 5/12/2006 | P | FAIL |
Jack Frank
|
|
|
craig; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. corr. not made 210.52(A) shall install outlet for wall space, 210.12 shall provide afci for all circuits in bed rm
|
Final | 5/9/2006 | 5/9/2006 | 5/9/2006 | P | NR |
Pat Lass
|
|
|
craig; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Lights not hung and recep under switch on outside wall not working. I had a conf and told him that he has to have lock-out in heater circuits and arc-fault on all circuits in bedroom.
|
Electrical Rough-In | 4/27/2006 | 4/27/2006 | 4/27/2006 | P | PASS |
Bob Reichert
|
|
|
corr made, ric ok
|
Electrical Rough-In | 4/26/2006 | 4/27/2006 | 4/27/2006 | A | NR |
Jack Frank
|
|
|
###-#### owner requested pm inspection, I added pm request
|
Electrical Rough-In | 4/24/2006 | 4/26/2006 | 4/26/2006 | A | FAIL |
Jack Frank
|
|
|
###-####; Phone #: ###-#### Internet Inspection Request from: Rita corr met owner, 210.52(A) outlet spacing everywhere, 300.4 nail plates and 11/4", 210.12 afci for all circuits in bed rm, 334.24 radius of cables, 334.80 not more than 2 cables in holes unless you derate, note update permit for 3 rms and up to 20kw of elect heat, install all boxes outside lignts, 314.16 box fill
|
Application received | | | 4/24/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 4/24/2006 | | DONE |
|
|
|
|