Final | 4/30/2007 | 4/30/2007 | 4/30/2007 | P | PASS |
Jack Frank
|
|
|
Brian call 30 minutes before; Phone #: ###-#### Internet Inspection Request from: Andrea Whiteman
|
Final | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | FAIL |
Jack Frank
|
|
|
brian - call 30 min prior; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called needs #8 equip grd manufactures instructions
|
Final | 4/9/2007 | 4/10/2007 | 4/10/2007 | A | FAIL |
Jack Frank
|
|
|
brian;Note: please call 1/2 hr prior to inspections Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr BCC contr shall secure permit and install wiring for hot tub owner wired, 110.3(B), shall use manufactures breakers only needs lockout for W H, 210.8 gfci for recept in bath shower area, 200.11 reversed polarity washer recept note all spa wiring shall meet NEC 680
|
Electrical Rough-In | 1/12/2007 | 1/16/2007 | 1/16/2007 | A | PASS |
Jack Frank
|
|
|
brian - pls call 30 min prior to inspection so brian can meet you at the site; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok
|
Electrical Rough-In | 1/11/2007 | 1/11/2007 | 1/11/2007 | P | FAIL |
Bob Reichert
|
|
|
brian - call 30 min prior to inspection please; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met owner, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(D) bath recpts shall be on wall or partition adjacent to basin, 210.52(A) recpts shall be installed on bedroom wall, BCC no violations shall be retained
|
Application received | | | 5/10/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 5/10/2006 | | DONE |
|
|
|
|