Second Notice ELE | 9/13/2006 | 9/13/2006 | 9/28/2006 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | 8/22/2006 | 8/22/2006 | 9/13/2006 | | DONE |
Jack Frank
|
|
|
|
Final | 8/21/2006 | 8/22/2006 | 8/22/2006 | A | PASS |
Jack Frank
|
|
|
ron - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
|
Final | 8/16/2006 | 8/17/2006 | 8/17/2006 | P | FAIL |
Jack Frank
|
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley see added r/i note only r/i inspections ever called in are for concrete encased electrode and u/g
|
Electrical Rough-In | 8/17/2006 | 8/17/2006 | 8/17/2006 | P | FAIL |
Jack Frank
|
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. called r/i inspection added 312.5 connector for GEC new building, old small building B C C no violations retained, 200.6 shall have required color for neutral, shall not ID 6 or smaller, 250.32 shall prvide made electrode, grd or bond water system if there, 225.31,32,36, 110.3(B), 408.34(A) shall provide service suitible for service equip as manufactures instructions state, note needs main breaker because it is not a power panelboard per manufactures instruction it is a lighting panelboard
|
Electrical Rough-In | 8/11/2006 | 8/14/2006 | 8/14/2006 | A | PART |
Jack Frank
|
|
|
RON nOTE: TRENCH; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles u/g ok
|
Electrical Rough-In | 8/1/2006 | 8/1/2006 | 8/1/2006 | P | FAIL |
Jack Frank
|
|
|
ron - trench ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr and don cover posted called 300.5 (F) needs bedding for u/g too many large rocks and paving material
|
Electrical Rough-In | 6/5/2006 | 6/6/2006 | 6/6/2006 | A | PART |
Jack Frank
|
|
|
slab inspection//ron wymer; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles inspection for electrode only
|
Application received | | | 5/30/2006 | | |
|
|
|
|
Issue permit | | | 5/30/2006 | | DONE |
|
|
|
|