Final | 11/3/2009 | 11/6/2009 | 11/6/2009 | A | PASS |
Doug A Poedy
|
|
|
Naomi- call 30 prior to going Phone #: ###-####. Ok final.
|
DOC - Permit Finaled | 11/6/2009 | 11/6/2009 | 11/6/2009 | P | PASS |
Doug A Poedy
|
|
|
|
Final | 9/18/2009 | 9/23/2009 | 9/23/2009 | P | NR |
Doug A Poedy
|
|
|
Naomi-after 3:30 please Phone #: ###-####--House addition only garage not complete yet. Still need to install some lighting.
|
Final | 4/3/2009 | 4/3/2009 | 4/3/2009 | P | CANC |
Pat Lass
|
|
|
naomi Phone #: ###-#### this was for a R/I
|
Electrical Rough-In | 4/3/2009 | 4/3/2009 | 4/3/2009 | P | PASS |
Pat Lass
|
|
|
naomi Phone #: ###-####
|
(F) Reprint permit | | | 4/3/2009 | | DONE |
|
|
|
|
Electrical Rough-In | 3/31/2009 | 4/1/2009 | 4/1/2009 | P | FAIL |
Bob Reichert
|
|
|
Naomi- 4pm if possible Phone #: ###-#### called, left message, left correction notice, NEC 210.52(A) shall space receptacle such that no point along wall line is over 6' from outlet (entry), 210.52(E) shall provide front and rear exterior receptacle, 410.8 shall ensure that closet fixture edge is at least 12" from shelf, BCC coiled wiring shall terminate in a box, shall provide smoke detector in front north room, shall update electrical permit to minimum 15 rooms
|
Conference | 3/26/2009 | 3/26/2009 | 3/26/2009 | P | NR |
Pat Lass
|
|
|
Jeff Phone #: ###-#### extension approved
|
Electrical Rough-In | 7/22/2008 | 7/25/2008 | 7/25/2008 | A | PASS |
William E Thomas
|
|
|
Naomi- call 30 prior to going Phone #: ###-#### . .1. ri ok. . .
|
Conference | 5/23/2008 | 5/27/2008 | 5/27/2008 | A | PART |
Pat Lass
|
|
|
naomi - please call 1/2 hr prior to inspection Phone #: ###-#### talked about ground wires make-up, nail plates and 6 in free conductor and required receps.
|
Conference | 11/9/2007 | 11/13/2007 | 11/13/2007 | A | NH |
Pat Lass
|
|
|
Naomi, please call; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called and got a mach. stopped at residence found no answer posted notice. ok to extend permit
|
Final | 5/31/2007 | 6/4/2007 | 6/4/2007 | A | NR |
Pat Lass
|
|
|
naomi To keep permit open; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
Extend Permit 180 days | 6/4/2007 | 6/4/2007 | 6/4/2007 | P | PASS |
Pat Lass
|
|
|
naomi To keep permit open; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
ELE-Request for Extension | 12/28/2006 | 12/28/2006 | 12/28/2006 | P | PASS |
Pat Lass
|
|
|
###-#### Naomi extend permit
|
Application received | | | 6/8/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/8/2006 | | DONE |
|
|
|
|