Final | 11/14/2006 | 11/14/2006 | 11/14/2006 | P | PASS |
Bob Reichert
|
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ok to final
|
Final | 9/19/2006 | 9/20/2006 | 9/20/2006 | A | FAIL |
Jack Frank
|
|
|
ped; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called still needs clearence for MB closet fixtures
|
Final | 9/18/2006 | 9/18/2006 | 9/18/2006 | P | FAIL |
Jack Frank
|
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. not made, 410.8 (A) needs clearence from storage space MB closet
|
Final | 9/14/2006 | 9/15/2006 | 9/15/2006 | A | FAIL |
Jack Frank
|
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. fee due corrections not made and created new one 410.8 clearence MB closet fixture, 314.16 box fill peninsular counter called
|
Reinspection Fee (no hold) | 9/15/2006 | 9/15/2006 | 9/15/2006 | A | DONE |
Jack Frank
|
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. fee due
|
Final | 9/5/2006 | 9/5/2006 | 9/5/2006 | P | FAIL |
Jack Frank
|
|
|
ted ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. called 410.8 clearence MB closet, 210.52(C)(5) except. outlet peninsular counter right of sink more than 6 ", 408.4 needs specific circuit directory, 314.29 entry light box buried
|
Electrical Rough-In | 6/19/2006 | 6/20/2006 | 6/20/2006 | A | PASS |
Jack Frank
|
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok
|
Stop Work/Reinspection Fee | 6/16/2006 | 6/16/2006 | 6/19/2006 | P | DONE |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles correction not 300.4(A)(1)&(D)
|
Rough-In Permanent Service | 6/16/2006 | 6/16/2006 | 6/16/2006 | P | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. not made fee due, called 300.4(A)(1)&(D) nail plates and 11/4" from inside and outside edges
|
Electrical Rough-In | 6/15/2006 | 6/15/2006 | 6/15/2006 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Shawna Hall corr. called 300.4 nail plates & 11/4" 314.20 all outside boxes shall be flush with siding, shall have p/s ready
|
Application received | | | 6/15/2006 | | DONE |
|
|
|
This permit was created on the web by Shawna Hall
|