Final | 11/16/2006 | 11/16/2006 | 11/16/2006 | P | PASS |
Jack Frank
|
|
|
mike - please call for access ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
|
Final | 11/14/2006 | 11/14/2006 | 11/14/2006 | P | NH |
Jack Frank
|
|
|
scott, please call 1st for access; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called left message for access no response had to leave the area
|
Final | 10/25/2006 | 10/25/2006 | 10/25/2006 | P | FAIL |
Jack Frank
|
|
|
mike; Phone #: ###-#### Note: please call to get in the house Internet Inspection Request from: Cathy Chiles corr. met contr, 110.3(B) manufactures instructions require a 30"x15" access for jtub, 210.52(C) needs required recept outlets counter in din rm, 408.4 circuit directory shall be specific for location, purpose and use fee due
|
Reinspection Fee (no hold) | 10/25/2006 | 10/25/2006 | 10/25/2006 | P | DONE |
Jack Frank
|
|
|
mike; Phone #: ###-#### Note: please call to get in the house Internet Inspection Request from: Cathy Chiles corr. fee due met contr
|
Electrical Rough-In | 7/21/2006 | 7/21/2006 | 7/21/2006 | P | PASS |
Bob Reichert
|
|
|
re-insp mike ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr made, ric ok
|
Permanent Service | 7/20/2006 | 7/20/2006 | 7/20/2006 | P | PASS |
Bob Reichert
|
|
|
p/s u/g n ok
|
Electrical Rough-In | 7/20/2006 | 7/20/2006 | 7/20/2006 | P | FAIL |
Bob Reichert
|
|
|
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(H) hall from garage shall have a recpt, 210.52(A) wall at top of stairs shall have recpts not over 6' from each other
|
Application received | | | 7/20/2006 | | |
|
|
|
|
Issue permit | | | 7/20/2006 | | DONE |
|
|
|
|