Final | 10/8/2007 | 10/9/2007 | 10/9/2007 | A | PASS |
Jack Frank
|
|
|
lloyd Phone #: ###-#### ok card signed
|
Final | 10/3/2007 | 10/4/2007 | 10/4/2007 | A | FAIL |
Jack Frank
|
|
|
lloyd Phone #: ###-#### 210.8 needs gfci all recepts garage, shop area, 334.15 protect horizontally ran cables in stud upstairs storage area, 406.8 needs inuse cover
|
Electrical Rough-In | 8/25/2006 | 8/28/2006 | 8/28/2006 | A | PASS |
Bob Reichert
|
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley told owner j-box by west exst wall shall be accessible, wire to short for rear exit light(not 6" in box), ric ok
|
Conference | 7/24/2006 | 7/25/2006 | 7/25/2006 | A | DONE |
Bob Reichert
|
|
|
###-#### lloyd talked about room and layout for recpts, subpanel and location, lighting, upstairs room, timing on permit before expires
|
Application received | | | 7/24/2006 | | |
|
|
|
|
Issue permit | | | 7/24/2006 | | DONE |
|
|
|
|
(F) Reprint permit | | | 7/24/2006 | | DONE |
|
|
|
|