Final | 10/23/2006 | 10/24/2006 | 10/24/2006 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 10/23/2006 at 5:59:10 PM. Contact: ###-####. corr made, ok to final
|
Final | 10/17/2006 | 10/18/2006 | 10/18/2006 | A | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 10/17/2006 at 9:50:06 PM. Contact: ###-####. left corr notice, told owner, nec 406.8 in-use cover shall be installed outside in wet area, 406.5 faceplates shall seat against mounting surfaces, 408.4 panel cover shall be installed and circuit directory shall be complete concise and explicit, for each circuit, 422.31 disconnect shall be installed for hot water heater, 210.8(A) gfci shall operate in bath and outside, 348.30 fmc shall be securely fastened within 12" of box
|
Electrical Rough-In | 8/23/2006 | 8/24/2006 | 8/24/2006 | A | PASS |
Jack Frank
|
|
|
whitney; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok
|
Electrical Rough-In | 8/20/2006 | 8/21/2006 | 8/21/2006 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 8/20/2006 at 10:01:22 PM. Contact: ###-####. corr. met owner 300.4 nail plates, 300.14 equip grds too short, 110.12 replace pastic boxes with extra KO s broken out
|
Electrical Rough-In | 8/15/2006 | 8/16/2006 | 8/16/2006 | A | NR |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 8/15/2006 at 5:35:33 PM. Contact: ###-####. requirements are not understood and homeowner not on site.left notice that howmowner shall be on site for inspection with Jace to clear up the problems. grounds just twisted together. parallel protection......
|
Electrical Rough-In | 8/10/2006 | 8/11/2006 | 8/11/2006 | A | NR |
Jack Frank
|
|
|
scheduled for 8-9 a.m per jack frank/// blb on 8/10/2006 Contact: ###-####. met owner needs makeup done some nail plates, and 11/4", outlet spacing
|
Final | 7/31/2006 | 8/1/2006 | 8/1/2006 | A | CANC |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 7/31/2006 at 2:42:09 PM. Contact: ###-####. see added conf.
|
Conference | 8/1/2006 | 8/1/2006 | 8/1/2006 | A | DONE |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 7/31/2006 at 2:42:09 PM. Contact: ###-####. ok
|
Application received | | | 7/31/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 7/31/2006 | | DONE |
|
|
|
|