Information based on query as of Sunday, August 18, 2024.
Permit Information
Permit NumberELE06-02921
StatusFinaled
Name ILLUMINATION INNOVATION
Site Address 3231 N COLE RD
Project NameCOLE VILLAGE
Customer Number 
ePlanReview 
Description
ti electrical : service, lighting, recepticles, rtu's per initial cert of value $30,000 ///Final value is $28,794//1/4/07 LEG
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice ELE12/26/200612/26/20061/4/2007 DONE
First Notice has not been responded to.
First Notice10/12/200610/12/200612/26/2006 DONE
DetailsBob Reichert
Final10/12/200610/12/200610/12/2006PPASS
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
Electrical Rough-In10/10/200610/11/200610/11/2006APASS
DetailsBob Reichert
mike Note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to finish cover clg
Permanent Service10/6/200610/6/200610/6/2006PPASS
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Patricia Smith p/s u/g n ok, 2 meters req'd, wrote corr notice nec 210.62 at least 1 recpt shall be installed for show windows 12' or fraction thereof
Electrical Rough-In9/28/20069/28/20069/28/2006PPASS
DetailsBob Reichert
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to cover clg, contr will leave tiles out for lv
Electrical Rough-In9/27/20069/27/20069/27/2006PNR
DetailsBob Reichert
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt elect was supposed to cancel, open boxes, securing mc cable, no lv wiring
Reinspection Fee (no hold)9/27/20069/27/20069/27/2006PNR
DetailsBob Reichert
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt elect was supposed to cancel
Reinspection Fee (no hold)9/15/20069/15/20069/15/2006PNR
DetailsBob Reichert
see ri, ceiling not done
Electrical Rough-In9/15/20069/15/20069/15/2006PNR
DetailsBob Reichert
mike Note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contr, left corr notice, fee due, nec 300.11 (A) support wires shall be secured at both ends, 330.30(A) cable shall be secured within12" of termination and not over 6', BCC work shall be ready for inspection and no remaining work to follow inspection
Conference8/28/20068/29/20068/29/2006ADONE
DetailsBob Reichert
Jared, consult on bonding & grounding; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt reviewed grounding requirements for new service
Electrical Rough-In8/22/20068/23/20068/23/2006APART
DetailsBob Reichert
jerod - Note: wall R/I; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles bath walls& clgs only , west walls only ok to cover
Electrical Rough-In8/22/20068/22/20068/22/2006PCANC
DetailsJack Frank
jerod; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
called wrong address there is no 3502
s cole
Application received  8/7/2006  
Issue permit  8/7/2006 DONE