Final | 3/26/2007 | 3/27/2007 | 3/27/2007 | A | FAIL |
Mike Kinnear
|
|
|
Priscilla..not for DPE is no longer in business. Using a diff company.; Phone #: ###-#### Internet Inspection Request from: Stacie Backus t/w building contractor new electrical contractor needs to get a permit for the work
|
Final | 2/5/2007 | 2/5/2007 | 2/5/2007 | P | CANC |
Bob Reichert
|
|
|
Priscilla ; Phone #: ###-#### Internet Inspection Request from: Darla Downs can per david not ready
|
Electrical Rough-In | 8/21/2006 | 8/21/2006 | 8/21/2006 | P | PASS |
Pat Lass
|
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
Electrical Rough-In | 8/18/2006 | 8/21/2006 | 8/21/2006 | P | CANC |
Jack Frank
|
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
Electrical Rough-In | 8/17/2006 | 8/18/2006 | 8/18/2006 | A | FAIL |
Pat Lass
|
|
|
Dan; Phone #: ###-#### Note: front house (cottage) ask for access Internet Inspection Request from: Cathy Weisshaupt protection of romex in several locations
|
Electrical Rough-In | 8/16/2006 | 8/17/2006 | 8/17/2006 | P | NH |
Jack Frank
|
|
|
Dan; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt notice posted called
|
Reinspection Fee (no hold) | 8/15/2006 | 8/15/2006 | 8/15/2006 | P | DONE |
Jack Frank
|
|
|
fee due posted
|
Electrical Rough-In | 8/14/2006 | 8/15/2006 | 8/15/2006 | P | FAIL |
Jack Frank
|
|
|
dan ###-#### corr. fee due called 314.16 box fill master bath, 250.122 use #12 for 20 amp equip grd pigtails, 300.4 nail plates and 11/4", 210.52(A) outlet spacing N W corner exercise rm, 314.17 (A&C) replace 2 gang boxes with broken clamps, 334,23 protect cables within 6 ft of attic access, note complete all wiring install all recess fixtures, update permit from 2rms to 11rms
|
Issue & PRINT permit | | | 8/14/2006 | | DONE |
|
|
|
|
Application received | | | 8/14/2006 | | |
|
|
|
|