Final | 5/3/2007 | 5/4/2007 | 5/4/2007 | A | PASS |
Pat Lass
|
|
|
Please call for access if you need. Thanks, Andrea. Phone #: ###-#### x0000 Internet Inspection Request from: Andrea Creek
|
Electrical Rough-In | 10/9/2006 | 10/10/2006 | 10/10/2006 | P | PASS |
Pat Lass
|
|
|
Thanks, Andrea.; Phone #: ###-#### Internet Inspection Request from: Andrea Creek
|
Electrical Rough-In | 10/9/2006 | 10/9/2006 | 10/9/2006 | P | FAIL |
Pat Lass
|
|
|
Thanks, Andrea.; Phone #: ###-#### Internet Inspection Request from: Andrea Creek remove wire from light box within 5 ft of hot tub install receps as required in 210.52
|
Permanent Service | 10/9/2006 | 10/9/2006 | 10/9/2006 | P | PASS |
Pat Lass
|
|
|
Thanks, Andrea.; Phone #: ###-#### Internet Inspection Request from: Andrea Creek P/S U/G N Ok
|
Electrical Rough-In | 10/6/2006 | 10/6/2006 | 10/6/2006 | P | FAIL |
Pat Lass
|
|
|
joe - ###-#### cell; Phone #: ###-#### Internet Inspection Request from: Patricia Smith add outlets 3rd and 1st floors install boxes for light fixture 3rd floor angle connector not permitted to be conceiled acorn connectors improperly used nail plates and parallel protectikon several places damaged outer sheath on feeder cable feeder cable shall be connected to service panel
|
Application received | | | 8/30/2006 | | DONE |
|
|
|
This permit was created on the web by Andrea Creek
|