First Notice | 12/21/2006 | 12/21/2006 | 1/12/2007 | | DONE |
Pat Lass
|
|
|
This permit finaled on the web by todd hall
|
Final | 12/20/2006 | 12/21/2006 | 12/21/2006 | A | PASS |
Pat Lass
|
|
|
Phone #: ###-#### Internet Inspection Request from: todd hall
|
Final | 12/19/2006 | 12/19/2006 | 12/19/2006 | P | NR |
Jack Frank
|
|
|
GC will have building open; Phone #: ###-#### Internet Inspection Request from: todd hall needs gfci for all kit recepts, bond hot and cold water
|
Final | 12/18/2006 | 12/19/2006 | 12/19/2006 | A | NH |
Jack Frank
|
|
|
Final inspect. Some exterior wall lights will not be installed till later date.; Phone #: ###-#### Internet Inspection Request from: todd hall no access called
|
Permanent Service | 11/28/2006 | 11/28/2006 | 11/28/2006 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: todd hall corrections made, p/s u/g n ok
|
Permanent Service | 11/27/2006 | 11/27/2006 | 11/27/2006 | P | FAIL |
Jack Frank
|
|
|
re-inspect for perm service. Please call Todd with result.; Phone #: ###-#### Internet Inspection Request from: todd hall corr. not made called
|
Permanent Service | 11/22/2006 | 11/24/2006 | 11/24/2006 | A | FAIL |
Jack Frank
|
|
|
Inspection for Perm Service. Please call Todd Hall with any questions ###-####; Phone #: ###-#### Internet Inspection Request from: todd hall fee due corr. called left message see added fee due inspection for notes
|
Reinspection Fee (no hold) | 11/24/2006 | 11/24/2006 | 11/24/2006 | A | FAIL |
Jack Frank
|
|
|
Inspection for Perm Service. Please call Todd Hall with any questions ###-####; Phone #: ###-#### Internet Inspection Request from: todd hall corr. called 250.24(A)(1)all GEC shall terminate at neutral bus 1 goes to enclosure , 1 to neutral bus both shall terminate at neutral bus
|
Electrical Rough-In | 11/8/2006 | 11/9/2006 | 11/9/2006 | A | PASS |
Jack Frank
|
|
|
re-inspect for building roughin. Please see AJ on site for inspection; Phone #: ###-#### Internet Inspection Request from: todd hall walls and ceiling ok
|
Electrical Rough-In | 11/7/2006 | 11/8/2006 | 11/8/2006 | A | FAIL |
Jack Frank
|
|
|
re-roughin for building; Phone #: ###-#### Internet Inspection Request from: todd hall corr. called still needs to strap MC within 12", still needs needs nail plates and 11/4" for MC parallel to studs, inside outside edges for nail plates
|
Electrical Rough-In | 11/3/2006 | 11/6/2006 | 11/6/2006 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: todd called, left message, left corr notice, nec 358.26 there shall not be over 360 degree bends in emt, 358.30(A) emt shall be securely fastened within 3' of box or termination point, 330.30(B) mc shall be securely supported within 12" of box, 300.4(A)&(D) edge of bored holes and mc cable shall be 1 1/4" from edge of framing members 250.86 all metal boxes shall be grounded
|
Reinspection Fee (no hold) | 11/3/2006 | 11/3/2006 | 11/3/2006 | A | DONE |
Jack Frank
|
|
|
aj ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr, met contr, 230.6 &70(A)(1) needs on outside service entrance conductor not allowed in building, 300.4 (A)(1)&(D) 330.30 MC strap within 12" of box. job not ready partial correction notice fee due
|
Electrical Rough-In | 11/2/2006 | 11/3/2006 | 11/3/2006 | A | FAIL |
Jack Frank
|
|
|
aj ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie see added fee due
|
Electrical Rough-In | 11/2/2006 | 11/2/2006 | 11/2/2006 | P | CANC |
Jack Frank
|
|
|
rough in inspect on Human Bean coffee drive thru; Phone #: ###-#### Internet Inspection Request from: todd hall Inspection cancelled from web by: Marsha Smylie
|
Electrical Rough-In | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | PASS |
Bob Reichert
|
|
|
please inspect uffer ground Call AJ with questions or problems; Phone #: ###-#### Internet Inspection Request from: todd hall ok to pour gec
|
Electrical Rough-In | 10/6/2006 | 10/9/2006 | 10/9/2006 | A | NR |
Jack Frank
|
|
|
please do ufer ground inspection; Phone #: ###-#### Internet Inspection Request from: todd hall fee due met contr.
|
Reinspection Fee (no hold) | 10/9/2006 | 10/9/2006 | 10/9/2006 | A | DONE |
Jack Frank
|
|
|
please do ufer ground inspection; Phone #: ###-#### Internet Inspection Request from: todd hall fee due job not ready met contr.
|
Electrical Rough-In | 10/6/2006 | 10/6/2006 | 10/6/2006 | P | PASS |
Bob Reichert
|
|
|
UNDERGROUND INSPECTION FOR POLE LIGHT; Phone #: ###-#### Internet Inspection Request from: todd hall ok to cover u/g conduit only, gec not done yet
|
Electrical Rough-In | 10/3/2006 | 10/4/2006 | 10/4/2006 | A | FAIL |
Jack Frank
|
|
|
please do trench inspection; Phone #: ###-#### Internet Inspection Request from: todd hall called u/g covered before inspection
|
Application received | | | 9/26/2006 | | DONE |
|
|
|
This permit was created on the web by todd hall
|