Electrical Rough-In | 5/3/2007 | 5/3/2007 | 5/3/2007 | P | PASS |
William E Thomas
|
|
|
dave ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ri ok
|
Electrical Rough-In | 4/27/2007 | 4/27/2007 | 4/27/2007 | P | CANC |
William E Thomas
|
|
|
thomas ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith 1. 210.52B1- breakfast area shall have 20amp cuircuit for all outlets. 2. 210.52C1- countertop receps 2'-4' rule 3. 210.52A2- wall space in kitchen shall have recepticle 4. 300.4A1- nail plates shall be used 5. 310.14- 6" free length of conductor
|
Electrical Rough-In | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | FAIL |
William E Thomas
|
|
|
thomas ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith there is still 15amp wire on 20amp circuits.
|
Electrical Rough-In | 4/20/2007 | 4/23/2007 | 4/23/2007 | A | FAIL |
William E Thomas
|
|
|
thomas; Phone #: ###-#### Internet Inspection Request from: Victoria Beall per thomas mullaney he talked w/ both pat and bill and he stated that they had told him to assign this inspection to bill thomas, that pat couldn't inspect it as bill had inspected it originally. this indeed up being a confrence, literaly talke about everything
|
Electrical Rough-In | 4/20/2007 | 4/20/2007 | 4/20/2007 | P | NR |
Pat Lass
|
|
|
Thomas; Phone #: ###-#### Internet Inspection Request from: Stacie Backus I talked with Thomas and looked at the job. I also called Bill. I told Bill and Thomas that It is best if Bill handel this because the work was incomplete when bill wrote the correction and I am umfamilier with that phase of the job and we need to have a face to face meeting because the use of different sizes of wire on circuits and the way circuits are run are hard to trace out. Thomas will reschedual for mon.
|
Electrical Rough-In | 4/16/2007 | 4/16/2007 | 4/16/2007 | P | FAIL |
William E Thomas
|
|
|
Thomas ; Phone #: ###-#### Internet Inspection Request from: Stacie Backus to many, consult notice that is posted
|
Conference | 3/5/2007 | 3/5/2007 | 3/5/2007 | P | DONE |
William E Thomas
|
|
|
thomas; Phone #: ###-#### Internet Inspection Request from: Victoria Beall they had no specific questions were requisting a confrence because the sheet said it was manditory.
|
Conference | 2/1/2007 | 2/1/2007 | 2/1/2007 | P | CANC |
Pat Lass
|
|
|
thomas; Phone #: ###-#### Internet Inspection Request from: Darla Downs thomas is unavailable.
|
Application received | | | 10/24/2006 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 10/24/2006 | | DONE |
|
|
|
|