Final | 3/23/2007 | 3/26/2007 | 3/26/2007 | A | PASS |
Jack Frank
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok
|
Final | 3/23/2007 | 3/23/2007 | 3/23/2007 | P | NR |
Jack Frank
|
|
|
Lars; Phone #: ###-#### Internet Inspection Request from: Stacie Backus needs under counter lights installed kit. called
|
Electrical Rough-In | 12/7/2006 | 12/7/2006 | 12/7/2006 | P | PASS |
Jack Frank
|
|
|
mike ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
|
Electrical Rough-In | 11/17/2006 | 11/17/2006 | 11/17/2006 | P | FAIL |
Jack Frank
|
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr. called 210.11(C)(2)&52(F) all recepts in laundry shall be on laundry circuit, 314.16 box fill , 300.4 nail plates and 11/4", 110.12(A) relace all plastic boxes with extra KOs broken out, cables sheath shall extent into box 1/4"314.20 boxes not flush furred out wall, 300.14 6" free length
|
Reinspection Fee (no hold) | 11/17/2006 | 11/17/2006 | 11/17/2006 | P | DONE |
Jack Frank
|
|
|
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr. fee due
|
Electrical Rough-In | 11/14/2006 | 11/14/2006 | 11/14/2006 | P | NH |
Jack Frank
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles notice posted called house is boarded up
|
Application received | | | 11/14/2006 | | |
|
|
|
|
Issue permit | | | 11/14/2006 | | DONE |
|
|
|
|