PRINT ACTIONS | | | 7/10/2008 | | DONE |
Alexandra L. DeYoung
|
|
|
|
Final | 8/2/2007 | 8/2/2007 | 8/2/2007 | P | PASS |
Bob Reichert
|
|
|
Rod ###-#### corr made, ok to final
|
Final | 7/31/2007 | 7/31/2007 | 7/31/2007 | P | FAIL |
Bob Reichert
|
|
|
rod Phone #: ###-#### called, left message, left corr notice, 406.8 (B) shall use enclosure that is weatherproof whether or not plug is inserted outdoor recpt, 410.8 shall either move or abandon light fixture in upstairs closet, 422.31(B) shall provide disconnect for water heater
|
Electrical Rough-In | 4/4/2007 | 4/5/2007 | 4/5/2007 | A | PASS |
Mike Kinnear
|
|
|
Rod; Phone #: ###-#### Internet Inspection Request from: Stacie Backus ok cover ri
|
Conference | 2/5/2007 | 2/5/2007 | 2/5/2007 | P | DONE |
Bob Reichert
|
|
|
Rod; Phone #: ###-#### Internet Inspection Request from: Darla Downs met contr to review scope of job, whether or not to change service depends on number of ckts he needs to add, and if change, to relocate, some rooms no work being done, won't add more recpts, several walls open, need to bring up tp code, may use wiremold for kitchen to bring to code
|
Application received | | | 2/5/2007 | | |
|
|
|
|
Issue permit | | | 2/5/2007 | | DONE |
|
|
|
|