Final | 7/24/2007 | 7/24/2007 | 7/24/2007 | P | PASS |
Pat Lass
|
|
|
###-#### garage code 1492 Internet Inspection Request from: Todd Holbrook ok with survey 210.8 (A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel. (7) Laundry, utility, and wet bar sinks - where the receptacles are installed within 1.8 m (6 ft) of the outside edge of the sink
|
Final | 7/10/2007 | 7/10/2007 | 7/10/2007 | A | NH |
Pat Lass
|
|
|
garage code 1492 questions ###-#### Internet Inspection Request from: Todd Holbrook no access floor being sealed
|
Permanent Service | 2/20/2007 | 2/20/2007 | 2/20/2007 | A | PASS |
Mike Kinnear
|
|
|
p/s u/g n ok
|
Electrical Rough-In | 2/19/2007 | 2/20/2007 | 2/20/2007 | A | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/19/2007 at 8:34:37 AM. Contact: ###-####. ok cover ri coreectiom made
|
Electrical Rough-In | 2/12/2007 | 2/12/2007 | 2/13/2007 | P | FAIL |
Pat Lass
|
|
|
ryan ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith Protect romex boxes over filled required receps in halls and sub panel clearance require. vacume outlet on small appliance circuit
|
Application received | | | 2/7/2007 | | DONE |
|
|
|
This permit was created on the web by Todd Holbrook
|