Final | 6/19/2007 | 6/20/2007 | 6/20/2007 | A | PASS |
William E Thomas
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot final ok
|
Conference | 6/5/2007 | 6/8/2007 | 6/6/2007 | A | CANC |
Pat Lass
|
|
|
Builder and electrician want to meet to discuss island outlets. Please call to confirm time. ###-#### Thank you Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot Inspection cancelled from web by: Barbara Szurgot
|
Electrical Rough-In | 5/23/2007 | 5/23/2007 | 5/23/2007 | A | PASS |
William E Thomas
|
|
|
inspection on pool lights Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot 1. potting compound ok
|
Permanent Service | 5/10/2007 | 5/11/2007 | 5/11/2007 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot p/s u/g new ok
|
Electrical Rough-In | 4/23/2007 | 4/23/2007 | 4/23/2007 | P | PASS |
William E Thomas
|
|
|
Inspection for equipotential grounding Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot grid ok
|
Electrical Rough-In | 4/9/2007 | 4/10/2007 | 4/10/2007 | A | PASS |
William E Thomas
|
|
|
trench inspection Phone #: ###-#### underground ok
|
Electrical Rough-In | 3/30/2007 | 4/2/2007 | 4/2/2007 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### r/i ok corrections made
|
Electrical Rough-In | 3/29/2007 | 3/30/2007 | 3/30/2007 | A | NR |
Pat Lass
|
|
|
rough in only Phone #: ###-#### contractor misunderstood requirements for protection from the outside of the building.
|
Rough-In Permanent Service | 3/28/2007 | 3/29/2007 | 3/29/2007 | A | FAIL |
Jack Frank
|
|
|
Rough in pool house and perm service. Thanks Phone #: ###-#### corr. fee due called 300.4 nail plates everywhere, 250.53(B) grd rod shall be 6 ft from footing (concrete encased electrode or remove it , not rquired), shall provide access to p/s and subpanel need ladderto get to them
|
Reinspection Fee (no hold) | 3/29/2007 | 3/29/2007 | 3/29/2007 | A | DONE |
Jack Frank
|
|
|
Rough in pool house and perm service. Thanks Phone #: ###-#### fee due corr. posted
|
Electrical Rough-In | 2/13/2007 | 2/13/2007 | 2/13/2007 | A | PART |
Pat Lass
|
|
|
Wasn''t sure what to call this inspection. Just need the pool bonding inspected. Thanks Phone #: ###-#### partial bonding of pool ok
|
Application received | | | 2/13/2007 | | DONE |
|
|
|
This permit was created on the web by Barbara Szurgot
|