Permit Information
Permit NumberELE07-00587
StatusFinaled
Name CENTERS ELECTRIC
Site Address 1625 S DENVER AVE
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: provide power for new detached garage
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/26/20077/27/20077/27/2007APASS
DetailsMike Kinnear
Reinspect for final please, garage access
52972. Thanks Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS ok final
Final7/25/20077/26/20077/26/2007AFAIL
DetailsMike Kinnear
JEFF Phone #: ###-####n nOTE: PLEASE CALL 1/2 HR PRIOR needs main disconnect at detached garage called t/w eric
Final7/16/20077/17/20077/17/2007ANH
DetailsWilliam E Thomas
Please inspect garage behind house access code for opener is 52972. thanks Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS
1. no one was home.
2. they had personel belongings in the garage, were the inspection was to take place.
Permanent Service4/13/20074/16/20074/16/2007ACANC
DetailsMike Kinnear
Reinspect ground wire installed for ufer thanks Phone #: ###-#### wrong type inspection
Electrical Rough-In4/16/20074/16/20074/16/2007PPASS
DetailsMike Kinnear
Reinspect ground wire installed for ufer thanks Phone #: ###-#### ok cover ground with concrete
Electrical Rough-In4/9/20074/10/20074/10/2007PFAIL
DetailsMike Kinnear
concrete incased electrode inspection Phone #: ###-#### area needs to be cleaned up of the dirt so the concrete came cover called left message
Rough-In Permanent Service3/27/20073/28/20073/28/2007PPASS
DetailsJack Frank
Need to inspect service change from 100 amp to 200 amp and inspect garage rough-in. Service change to start first thing in morning, should be ready early pm. thanks. Phone #: ###-#### needs to add p/s for garage to permit, or get new permit for garage, allso needs concrete encased electrode for garage, p/s o/h rec. for house ok
Electrical Rough-In3/23/20073/26/20073/26/2007APASS
DetailsWilliam E Thomas
Underground conduit inspection Phone #: ###-####
ug conduit ok
Application received  2/21/2007 DONE
This permit was created on the web by ERIC CENTERS