Final | 4/19/2007 | 4/19/2007 | 4/19/2007 | P | PASS |
Bob Reichert
|
|
|
Glen; Phone #: ###-#### Internet Inspection Request from: Stacie Backus corr made, ok to final
|
Final | 4/18/2007 | 4/18/2007 | 4/18/2007 | P | FAIL |
Bob Reichert
|
|
|
glenn ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left corr notice, nec 406.4 recpts shall be securely fastened and mounted, 406.4(D) recpts shall be flush with or project from faceplates, 110.22 each disconnect shall be legibly marked to indicate it's purpose, 410.8(A) edge of fixture shall be min 12" from edge of shelf
|
Electrical Rough-In | 2/26/2007 | 2/26/2007 | 2/26/2007 | P | PASS |
Bob Reichert
|
|
|
glenn ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok, corr made, called about couple nail plates
|
Electrical Rough-In | 2/23/2007 | 2/26/2007 | 2/26/2007 | A | FAIL |
Pat Lass
|
|
|
lynn ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith protection of romex
|
Rough-In Permanent Service | 2/22/2007 | 2/22/2007 | 2/22/2007 | P | CANC |
Bob Reichert
|
|
|
glen - and grounding; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see ri and p/s
|
Electrical Rough-In | 2/22/2007 | 2/22/2007 | 2/22/2007 | P | FAIL |
Bob Reichert
|
|
|
glen - and grounding; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, left corr notice, NEC 110.12(C) there shall be no broken parts, 210.52(A)(1) recpt shall be installed so no point is over 6' along floor line from outlet, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member,BCC all u/g shall be inspected before cover
|
Permanent Service | 2/22/2007 | 2/22/2007 | 2/22/2007 | P | PASS |
Bob Reichert
|
|
|
glen - and grounding; Phone #: ###-#### Internet Inspection Request from: Victoria Beall p/s u/g n ok
|
Application received | | | 2/22/2007 | | |
|
|
|
|
Issue permit | | | 2/22/2007 | | DONE |
|
|
|
|