Permit Information
Permit NumberELE07-00654
StatusFinaled
Name BOISE ELECTRIC
Site Address 6102 W POST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/19/20074/19/20074/19/2007PPASS
DetailsBob Reichert
Glen; Phone #: ###-#### Internet Inspection Request from: Stacie Backus corr made, ok to final
Final4/18/20074/18/20074/18/2007PFAIL
DetailsBob Reichert
glenn ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left corr notice, nec 110.22 each disconnect shall be legibly marked to indicate it's purpose,406.5 faceplates shall seat against mounting surface, 410.8(A) edge of fixture in closet shall be min 12" from edge of shelf
Permanent Service3/9/20073/9/20073/9/2007PPASS
DetailsBob Reichert
glen; Phone #: ###-#### Internet Inspection Request from: Stacie Backus p/s u/g n ok
Rough-In Permanent Service3/6/20073/6/20073/6/2007PPART
DetailsJack Frank
glenn; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
concrete encased electrode ok
Rough-In Permanent Service2/28/20072/28/20072/28/2007PCANC
DetailsBob Reichert
glen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, gec not poured, therefore ric only, see ri, will do gec ltr
Electrical Rough-In2/27/20072/28/20072/28/2007ACANC
DetailsBob Reichert
Glen grounding and rough in; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, wrong address
Application received  2/27/2007  
Override - Parcel Holds  2/27/2007  
NOthing to do with parcel hold
Issue permit  2/27/2007 DONE