Final | 4/23/2007 | 4/23/2007 | 4/23/2007 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman ok to final, met elect to fix cover plates
|
Rough-In Permanent Service | 3/12/2007 | 3/12/2007 | 3/12/2007 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### ric ok, p/s u/g n ok, 4 meters
|
Electrical Rough-In | 3/8/2007 | 3/9/2007 | 3/9/2007 | A | FAIL |
Jack Frank
|
|
|
SEAN; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr. called 300.4 nail plates 11/4", 210.52(A&B) small appliance branch circuit recept shall not serve wall space in liv. rm, 210.25 shall install common area service for outside outlet installed for catv, or remove outlet, BCC shall complete all makeup outside boxes
|
Electrical Rough-In | 3/8/2007 | 3/8/2007 | 3/8/2007 | P | CANC |
Bob Reichert
|
|
|
sean; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called contr, told no bld, told to find out about and recall for inspection
|
Application received | | | 3/8/2007 | | |
|
|
|
|
Issue permit | | | 3/8/2007 | | DONE |
|
|
|
|