Final | 8/28/2007 | 8/28/2007 | 8/28/2007 | P | PASS |
William E Thomas
|
|
|
DON Phone #: ###-#### 1. final ok.
|
(F) Reprint permit | | | 8/23/2007 | | DONE |
|
|
|
|
Electrical Rough-In | 7/23/2007 | 7/23/2007 | 7/23/2007 | P | PASS |
Bob Reichert
|
|
|
julie Phone #: ###-#### corrections made, had owner move jb for 6" free conductor length
|
Final | 7/12/2007 | 7/13/2007 | 7/13/2007 | A | NR |
Jack Frank
|
|
|
don Phone #: ###-#### see added r/i note complete all make up
|
Electrical Rough-In | 7/13/2007 | 7/13/2007 | 7/13/2007 | A | FAIL |
Jack Frank
|
|
|
don Phone #: ###-#### corr. 300.4 provide 11/4" for cables parallel210.52(A) outlet spacing, 210.11(C)(3) needs 20 amp bath circuit, 110.3(B) use manufactures breakers only, BCC no violations retainedcorrect wiring to garage that owner replace and address new panel in garage shall meet NEC cow
|
Conference | 6/14/2007 | 6/15/2007 | 6/15/2007 | A | DONE |
Bob Reichert
|
|
|
julie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles talked about ckt extension, when to call for ri
|
Application received | | | 3/23/2007 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 3/23/2007 | | DONE |
|
|
|
|
(F) Reprint permit | | | 3/23/2007 | | DONE |
|
|
|
|