Final | 5/24/2007 | 5/24/2007 | 5/24/2007 | P | PASS |
Bob Reichert
|
|
|
Final Inspection. Please call Steve Ruter to get access Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson ok to final
|
Electrical Rough-In | 5/14/2007 | 5/14/2007 | 5/14/2007 | P | PASS |
William E Thomas
|
|
|
Underground & pool grid bonding inspection. Please Call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson equipotential grid ok
|
Electrical Rough-In | 5/11/2007 | 5/14/2007 | 5/14/2007 | A | FAIL |
Jack Frank
|
|
|
Underground & pool grid bonding inspection. Please Call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr. not made, still needs to install rebar for 12" squares where required, tie all rebar together, and bond pool cover rails together
|
Reinspection Fee (no hold) | 5/14/2007 | 5/14/2007 | 5/14/2007 | A | DONE |
Jack Frank
|
|
|
Underground & pool grid bonding inspection. Please Call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr not made and not ready
|
Electrical Rough-In | 5/10/2007 | 5/11/2007 | 5/11/2007 | A | FAIL |
Bob Reichert
|
|
|
Underground & Pool Grid bonding inspection. Please call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson called, left corr notice, nec 680.26(B) news breif, rebar shall have minimum 12" squares and be tied at each cross, called contr to verify split bolt listed for rebar and for being poured in concrete
|
Electrical Rough-In | 5/1/2007 | 5/2/2007 | 5/2/2007 | A | PASS |
Bob Reichert
|
|
|
R.I. underground conduits by house. Please call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson ok to cover u/g by house
|
Electrical Rough-In | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | PASS |
Bob Reichert
|
|
|
Rough in underground conduit. Please call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr made ok to cover u/g pad to pool
|
Electrical Rough-In | 4/24/2007 | 4/25/2007 | 4/25/2007 | A | FAIL |
Bob Reichert
|
|
|
Rough Inspect underground for pool lights and sub panel inspection. Please Call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson called contr about u/g from pad, nec 352.26 there shall not be over 360 degree bends in rnc, 680.10 there shall be no u/g wiring within 5' of inside wall of pool, told pool man could work around pool shell only
|
Application received | | | 4/24/2007 | | DONE |
|
|
|
This permit was created on the web by Kristopher Wilson
|