Electrical Rough-In | 5/30/2007 | 5/31/2007 | 5/31/2007 | P | PASS |
William E Thomas
|
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ri ok, basement area only.
|
Electrical Rough-In | 5/30/2007 | 5/30/2007 | 5/30/2007 | P | FAIL |
Bob Reichert
|
|
|
brandon ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left corr notice, nec 210.52(A)(1)(2) recpts shall be installed in any wall over 2' and 6' from entry- east side, before beds, 210.52(H) recpt shall be installed in hall over 10', 110.26 shall provide clearance and space in front of panel, 210.70(A)(2)(c) shall provide stair lighting and switching, 334.30 nm cable shall not be stapled on edge(bath), BCC shall repair rept for water softener and dryer-mounting and no taps off dryer ckt
|
Application received | | | 5/30/2007 | | |
|
|
|
|
Issue permit | | | 5/30/2007 | | DONE |
|
|
|
|