Permanent Service | 6/19/2007 | 6/20/2007 | 6/20/2007 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 6/19/2007 at 4:31:58 PM. Contact: ###-####. p/s o/h new ok
|
Permanent Service | 6/18/2007 | 6/18/2007 | 6/18/2007 | P | FAIL |
Bob Reichert
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections not done for bond bushings, and abrasion protection, called owner
|
Final | 6/18/2007 | 6/18/2007 | 6/18/2007 | P | CANC |
Bob Reichert
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called told owner ok for ri, recall p/s, wrong type request
|
Electrical Rough-In | 6/18/2007 | 6/18/2007 | 6/18/2007 | P | PASS |
Bob Reichert
|
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok
|
Electrical Rough-In | 6/13/2007 | 6/14/2007 | 6/14/2007 | A | FAIL |
Bob Reichert
|
|
|
Michael ###-#### called , left corr notice, nec 312.5 abrasion protection shall be provided for all conductors entering enclosures, 250.86 metal enclosures shall be grounded, 250.92(B) bonding jumpers shall be provided around concentrics at service, 314.17(B) jacket shall extend min 1/4" inside box, 310.70(A)(2)(b) at least 1 switched outdoor light shall be provided at man door to garage, BCC all make-up shall be done, minimum 2" riser shall be provided for riser at service, approved guy kit shall be provided, called to install gnd wire in hollow part of ground clamp
|
Conference | 6/6/2007 | 6/7/2007 | 6/7/2007 | P | DONE |
William E Thomas
|
|
|
michael ###-####-- call 1st before insp the owner was in nampa when I called. He had no direct questions and said he was familiar with what was needed and would schedule a confrence when he actually had some work done for us to look at.
|
Issue PAID IN FULL permit | | | 6/6/2007 | | |
|
|
|
|
Application received | | | 6/6/2007 | | |
|
|
|
|