Final | 3/3/2020 | 3/3/2020 | 3/3/2020 | P | PASS |
Mark Moncarr
|
|
|
Steve Phone #: ###-#### Ok final. Was able to get to most everything. Everything checked out ok. TR used, GFI functioning and AC brkr a 40 but fused with 30's.
|
ELE-Aging Inspection | 2/20/2020 | 2/20/2020 | 2/20/2020 | | PASS |
Tom Saunders
|
|
|
waiting on permit holder
|
ELE-Aging Inspection | 11/21/2019 | 11/21/2019 | 11/22/2019 | | DONE |
Tom Saunders
|
|
|
waiting on homeowner
|
ELE-Aging Inspection | 8/22/2019 | 8/22/2019 | 8/22/2019 | | PASS |
Tom Saunders
|
|
|
still under construction...permit reopened as per Bob Archibald 8/21/19
|
Change Status to I | | | 8/21/2019 | | DONE |
|
|
|
reopened permit per Bob Archibald. See activities in BLD07-01179
|
ELE-Aging Inspection | 2/5/2016 | 2/5/2016 | 2/5/2016 | | PASS |
Rock A. Hudson
|
|
|
BLD expired
|
DOC - Permit Expired | 2/5/2016 | 2/5/2016 | 2/5/2016 | P | PASS |
Rock A. Hudson
|
|
|
BLD and all other permits expired.
|
ELE-Aging Inspection | 11/6/2015 | 11/6/2015 | 11/6/2015 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 8/7/2015 | 8/7/2015 | 8/7/2015 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 5/8/2015 | 5/8/2015 | 5/8/2015 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 2/6/2015 | 2/6/2015 | 2/6/2015 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 11/7/2014 | 11/7/2014 | 11/7/2014 | | DONE |
Rock A. Hudson
|
|
|
Still under construction
|
ELE-Aging Inspection | 8/8/2014 | 8/8/2014 | 8/11/2014 | | DONE |
Daryl DeGrange
|
|
|
Home owner believes hes within 30 days of completion
|
ELE-Aging Inspection | 4/30/2014 | 4/30/2014 | 5/2/2014 | | DONE |
Daryl DeGrange
|
|
|
still under construction, but lose
|
ELE-Aging Inspection | 1/29/2014 | 1/29/2014 | 1/31/2014 | | DONE |
Daryl DeGrange
|
|
|
Called contact person, anwered some questions. job maybe ready for inspection this spring.
|
ELE-Aging Inspection | 10/30/2013 | 10/30/2013 | 10/31/2013 | | DONE |
Daryl DeGrange
|
|
|
still under construction
|
ELE-Aging Inspection | 7/31/2013 | 7/31/2013 | 7/31/2013 | | DONE |
Daryl DeGrange
|
|
|
Called left message for homeowner
|
ELE-Aging Inspection | 4/22/2013 | 4/22/2013 | 4/22/2013 | | DONE |
Daryl DeGrange
|
|
|
homeowner said still under construction
|
ELE-Aging Inspection | 1/21/2013 | 1/21/2013 | 1/25/2013 | | DONE |
Daryl DeGrange
|
|
|
still under construction, at sheet rock stage
|
Electrical Rough-In | 9/14/2012 | 9/14/2012 | 9/14/2012 | P | PASS |
Bob Reichert
|
|
|
Steve or Jack Phone #: ###-#### #3 bedroom and hall ok cover
|
Electrical Rough-In | 7/3/2012 | 7/3/2012 | 7/3/2012 | P | PASS |
Daryl DeGrange
|
|
|
STEVE Phone #: ###-#### rough-in ok cover
|
ELE-Aging Inspection | 4/25/2012 | 4/25/2012 | 4/27/2012 | | CANC |
Jack Frank
|
|
|
|
ELE-Aging Inspection | 1/25/2012 | 1/25/2012 | 1/25/2012 | | DONE |
Jack Frank
|
|
|
|
ELE-Aging Inspection | 10/17/2011 | 10/17/2011 | 10/19/2011 | | CANC |
Jack Frank
|
|
|
|
ELE-Aging Inspection | 7/18/2011 | 7/18/2011 | 7/18/2011 | | CANC |
Jack Frank
|
|
|
not my job anymore
|
ELE-Aging Inspection | 4/18/2011 | 4/18/2011 | 4/18/2011 | | DONE |
Jack Frank
|
|
|
not my job anymore
|
ELE-Aging Inspection | 2/16/2011 | 2/16/2011 | 2/16/2011 | | DONE |
Jack Frank
|
|
|
wsuc
|
ELE-Aging Inspection | 12/6/2010 | 12/6/2010 | 12/6/2010 | | CANC |
Jack Frank
|
|
|
|
ELE-Aging Inspection | 10/4/2010 | 10/4/2010 | 10/6/2010 | | CANC |
Doug A Poedy
|
|
|
|
Electrical Rough-In | 8/2/2010 | 8/2/2010 | 8/2/2010 | P | PASS |
Bob Reichert
|
|
|
Steve Phone #: ###-#### corrections made, ri bathroom ok
|
Electrical Rough-In | 7/28/2010 | 7/29/2010 | 7/29/2010 | P | FAIL |
Doug A Poedy
|
|
|
Steve Phone #: ###-####. Needs to move 6 romexes out of one hole. Has 10 romexes in one hole in bathroom.
|
Electrical Rough-In | 6/18/2010 | 6/21/2010 | 6/21/2010 | P | PASS |
Doug A Poedy
|
|
|
Steve Phone #: ###-####. Ok for cover. verbal survey to change out range wire.
|
Conference | 5/6/2010 | 5/6/2010 | 5/6/2010 | P | CANC |
Doug A Poedy
|
|
|
steve Phone #: ###-####
|
Electrical Rough-In | 3/19/2010 | 3/19/2010 | 3/19/2010 | P | FAIL |
Jack Frank
|
|
|
Steve or Jack Phone #: ###-#### job still not ready and violations loose splices, countertop outlet spacing, makeup not complete , are some of the violations, job is a mess
|
Electrical Rough-In | 3/11/2010 | 3/11/2010 | 3/11/2010 | P | FAIL |
Jack Frank
|
|
|
steve Phone #: ###-#### met owner all wiring in violation of NEC see JFrank for details too much to note. called DPoedy , he will contact owner
|
Change Status to I | | | 3/11/2010 | | DONE |
|
|
|
inspector signed off on temp serv which finaled this permit - this permit was not ready to be finaled ///3-11-10ps
|
Temporary Service | 10/14/2008 | 10/14/2008 | 10/14/2008 | P | PASS |
Bob Reichert
|
|
|
steve Phone #: ###-#### t/s u/g n ok
|
Conference | 10/7/2008 | 10/8/2008 | 10/8/2008 | A | DONE |
Bob Reichert
|
|
|
steve Phone #: ###-#### met with owner, talked about t/s and using existing direct burial cable from ipco to feed temp pole. Talked about if mounting secure for t/s, said would probably work as mounted
|
Conference | 9/29/2008 | 9/30/2008 | 9/30/2008 | A | DONE |
Bob Reichert
|
|
|
steve- call 1st before insp Phone #: ###-#### talked about re-locating and putting in new service, contact ipco, when to call for inspection, grounding, range, dryer, sub-panel, check with gas company,
|
(F) Reprint permit | | | 9/29/2008 | | |
|
|
|
|
Electrical Rough-In | 3/27/2008 | 3/28/2008 | 3/28/2008 | P | PASS |
Bob Reichert
|
|
|
steve Phone #: ###-#### met owner, corrections made, ric ok west 1/2 house, bedroom and bath
|
Electrical Rough-In | 3/24/2008 | 3/24/2008 | 3/24/2008 | P | FAIL |
Bob Reichert
|
|
|
steve Phone #: ###-#### met owner , corrections, NEC 210.52 outlet spacing shall be wothin 6' in wall space, 110.12(C) there shall be no broken boxes,BCC all make-up shall be done
|
Electrical Rough-In | 11/21/2007 | 11/21/2007 | 11/21/2007 | P | PASS |
Bob Reichert
|
|
|
Steve Phone #: ###-#### corrections made, ok to cover master bedroom and closet only
|
Electrical Rough-In | 11/13/2007 | 11/14/2007 | 11/14/2007 | P | FAIL |
Bob Reichert
|
|
|
Steve Phone #: ###-#### BCC all make-up shall be done, no devices installed, NEC 250.86 shall provide and wire ground wire in metal boxes, 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing members, 300.14 at 6" free conductor shall be provided before tails installed
|
Conference | 6/12/2007 | 6/13/2007 | 6/13/2007 | A | DONE |
Bob Reichert
|
|
|
steve ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith reviewed wiring will mostly be done by father-in-laww living in house, talked about code and inspections
|
Issue PAID IN FULL permit | | | 6/8/2007 | | DONE |
|
|
|
|
Application received | | | 6/7/2007 | | |
|
|
|
|