Permanent Service | 6/19/2007 | 6/20/2007 | 6/20/2007 | A | PASS |
Jack Frank
|
|
|
electrician is Nick Felsted Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer see added r/i for corr p/s u/g new ok
|
Electrical Rough-In | 6/20/2007 | 6/20/2007 | 6/20/2007 | P | FAIL |
Jack Frank
|
|
|
electrician is Nick Felsted Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer300.4 nail plates and 11/4" for SER garage, 312.5 conn for SER at p/s, and MNB not allowed in conduit from subpanel to basement old p/s jbox, 300.3(B) pump wiring, 250.52(A) jumper around flex wter pipe basement, 110.12(A) seal all unused KOs and conduits, church shall secure licensed elect contr to install u/g for pole light, all pole light wiring in violation covered before inspection no permit
|
Reinspection Fee (no hold) | 6/20/2007 | 6/20/2007 | 6/20/2007 | A | DONE |
Jack Frank
|
|
|
electrician is Nick Felsted Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer fee due
|
Permanent Service | 6/18/2007 | 6/18/2007 | 6/18/2007 | P | FAIL |
Jack Frank
|
|
|
Nick Felsted / electrician Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer not ready no access
|
Reinspection Fee (no hold) | 6/18/2007 | 6/18/2007 | 6/18/2007 | P | DONE |
Jack Frank
|
|
|
Nick Felsted / electrician Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer not ready and mo access
|
Application received | | | 6/18/2007 | | DONE |
|
|
|
This permit was created on the web by Jarrod Clymer
|