Final | 8/8/2007 | 8/9/2007 | 8/9/2007 | A | PASS |
Jack Frank
|
|
|
reinspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers ok corrections made
|
Final | 8/7/2007 | 8/8/2007 | 8/8/2007 | A | FAIL |
Jack Frank
|
|
|
final inspection on swimming pool Phone #: ###-#### Internet Inspection Request from: Jari Rivers called left message, 250.32(B)(1) shall isolate grds and neugtrals at pool panel, 680.22(A)(3) needs gfci recept 10ft 20 ft for pool
|
Reinspection Fee (no hold) | 8/8/2007 | 8/8/2007 | 8/8/2007 | A | DONE |
Jack Frank
|
|
|
final inspection on swimming pool Phone #: ###-#### Internet Inspection Request from: Jari Rivers fee due correcton
|
Electrical Rough-In | 7/23/2007 | 7/24/2007 | 7/24/2007 | A | PASS |
William E Thomas
|
|
|
Potential plane, potting, light and capsulation re-inspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers bonding and potting ok
|
Electrical Rough-In | 7/22/2007 | 7/23/2007 | 7/23/2007 | A | FAIL |
William E Thomas
|
|
|
Equal potential plane, potting, light & capsulation inspection on swimming pool Phone #: ###-#### Internet Inspection Request from: Jari Rivers 1. not ready, and they didnot call to let us know. 2. re-inspection fee assessed
|
Reinspection Fee (no hold) | 7/23/2007 | 7/23/2007 | 7/23/2007 | P | DONE |
William E Thomas
|
|
|
Equal potential plane, potting, light & capsulation inspection on swimming pool Phone #: ###-#### Internet Inspection Request from: Jari Rivers 1. not ready for inspection.
|
Electrical Rough-In | 7/6/2007 | 7/9/2007 | 7/9/2007 | A | PART |
Jack Frank
|
|
|
Electrical cover inspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers u/g ok only, no e grid
|
Electrical Rough-In | 7/3/2007 | 7/5/2007 | 7/5/2007 | P | PART |
Jack Frank
|
|
|
Cancle prior inspection made for thurs Am and change to thursday Pm Bonding inspection. Thank you Phone #: ###-#### Internet Inspection Request from: Jari Rivers pool bond only ok
|
Electrical Rough-In | 6/29/2007 | 7/5/2007 | 7/5/2007 | A | CANC |
Jack Frank
|
|
|
bonding inspection on swimming pool for thursday July 5, Phone #: ###-#### Internet Inspection Request from: Jari Rivers
|
Application received | | | 6/28/2007 | | |
|
|
|
|
Issue permit | | | 6/28/2007 | | |
|
|
|
|