Second Notice ELE | 11/15/2007 | 11/15/2007 | 11/20/2007 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | 10/22/2007 | 10/22/2007 | 11/15/2007 | | DONE |
Bob Reichert
|
|
|
|
Final | 10/22/2007 | 10/22/2007 | 10/22/2007 | P | PASS |
Bob Reichert
|
|
|
Thank You!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok to final, signed occupancy card
|
Electrical Rough-In | 10/4/2007 | 10/4/2007 | 10/4/2007 | P | PASS |
Bob Reichert
|
|
|
Service Inspection please. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson p/s, exst meter pak, n, ok, 1 meter only
|
Electrical Rough-In | 8/14/2007 | 8/15/2007 | 8/15/2007 | A | PASS |
Bob Reichert
|
|
|
rough in for walls Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr made, ric walls only ok
|
Electrical Rough-In | 8/13/2007 | 8/14/2007 | 8/14/2007 | A | FAIL |
Jack Frank
|
|
|
rough-in for walls. Call Todd if any problems Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr. met contr. 600.5 shall provide required sign circuit, 300.4 (A)(1)&(D) nail plates and 11/4" for cables parallel to studs, 110.26(F)(2) remove sprinkler wiring from below outside panel, 110.12(A) seal KO subpanel, do not cover posted
|
Rough-In Permanent Service | 8/10/2007 | 8/13/2007 | 8/13/2007 | A | FAIL |
Bob Reichert
|
|
|
Walls only inspection please!! Thanks Phone #: ###-#### Internet Inspection Request from: Tracy Robertson called, left corr notice, fee due, BCC shall post address, shall provide access, shall correct permit such that only 1 t.i. shall be listed for permit
|
Reinspection Fee (no hold) | 8/13/2007 | 8/13/2007 | 8/13/2007 | A | CANC |
Bob Reichert
|
|
|
Walls only inspection please!! Thanks Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see failed inspection
|
Rough-In Permanent Service | 8/7/2007 | 8/7/2007 | 8/7/2007 | P | CANC |
Jack Frank
|
|
|
Bob - WALLS ONLY. Thank You!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson needs seperate ele permits foe each T?I and shall be linked to correct BLD permit, and plans shall have reversed north south corrected
|
Rough-In Permanent Service | 8/7/2007 | 8/7/2007 | 8/7/2007 | A | CANC |
Bob Reichert
|
|
|
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
Rough-In Permanent Service | 7/31/2007 | 8/1/2007 | 8/1/2007 | A | CANC |
Bob Reichert
|
|
|
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson met contr, said they wanted to cancel inspection
|
Permanent Service | 7/10/2007 | 7/10/2007 | 7/10/2007 | P | CANC |
William E Thomas
|
|
|
Under-slab insp please. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson this should be a rough in
|
Electrical Rough-In | 7/10/2007 | 7/10/2007 | 7/10/2007 | P | PASS |
William E Thomas
|
|
|
Under-slab insp please. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson under slab ok
|
Electrical Rough-In | 6/29/2007 | 7/2/2007 | 7/2/2007 | A | CANC |
Bob Reichert
|
|
|
Inspection for underslab with floor box locations. Please schedule to inspect late morning Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
Application received | | | 6/29/2007 | | DONE |
|
|
|
This permit was created on the web by Tracy Robertson
|