Permit NumberELE07-02351
StatusFinaled
Name JAMES ROSS
Site Address 10940 W HOLLANDALE DR
Project Name 
Customer Number 
ePlanReview 
Description
wiring of the detached building
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/15/20078/15/20078/15/2007PPASS
DetailsBob Reichert
Carol; Phone #: ###-#### Internet Inspection Request from: Hattie James corrections made, ok to final
Final8/14/20078/14/20078/14/2007PFAIL
DetailsBob Reichert
Cell: ###-####; Carol; Phone #: ###-#### Internet Inspection Request from: Hattie James called, left corr notice, nec 406.8(B) recpts in wet location shall have enclosure that is weatherproof whether or not plug inserted, 210.8(A)(2) gfci shall be provided for all recpts in garage or accessory bldg
Electrical Rough-In8/6/20078/6/20078/6/2007PPASS
DetailsBob Reichert
carol - re-inspection Phone #: ###-#### corrections made, ric ok
Electrical Rough-In8/2/20078/2/20078/2/2007PFAIL
DetailsBob Reichert
carol Phone #: ###-#### met owner, left corr notice, nec 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing members, 110.26(A) shall provide work space in front of sub-panel in garage
Conference7/2/20077/3/20077/3/2007PDONE
DetailsBob Reichert
James ###-#### talked about inside wiring for new storage building or shop, owner said service will be by others, said to watch for 1 1/4" make-up free conductor length, told owner if only 1 recpt on 20a ckt, then shall have 20a recpt, but if more than one recpt, can be 15a
Issue PAID IN FULL permit  7/2/2007 DONE
Application received  7/2/2007