Final | 9/17/2007 | 9/17/2007 | 9/17/2007 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Monty Adkinson called contr about dishwasher lock-out, ok to final
|
Electrical Rough-In | 7/17/2007 | 7/17/2007 | 7/17/2007 | A | PASS |
Bob Reichert
|
|
|
kitchen, dining, entry work, corrections made. Phone #: ###-#### Internet Inspection Request from: Monty Adkinson corrections made, ric ok
|
Electrical Rough-In | 7/16/2007 | 7/16/2007 | 7/16/2007 | A | FAIL |
Bob Reichert
|
|
|
need cover inspection in exposed areas, added recessed cans are cut in through existing sheetrock in dining and entry areas Phone #: ###-#### Internet Inspection Request from: Monty Adkinson called, left message, left corr notice, nec 110.12(C) there shall be no broken parts or equipment, i.e. box shall not have clamps broken out, nm cable shall not have damaged jacketing, 300.4(D) nm cable shall be 1 1/4" from edge of framing member
|
Application received | | | 7/16/2007 | | DONE |
|
|
|
This permit was created on the web by Monty Adkinson
|