Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE07-02696
StatusFinaled
Name L & K ELECTRIC
Site Address 2584 S MAYFLOWER WAY
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/7/20079/10/20079/10/2007APASS
DetailsBob Reichert
This will be for a final on this job. Justin Metcalf is the contact. Thank you very much
Phone #: ###-#### Internet Inspection Request from: Laura Longshaw called contr, left message for 2 recpts with open grounds, met owner told to let know if contr didn't fix, survey, ok to final
Electrical Rough-In8/6/20078/6/20078/6/2007PPASS
DetailsBob Reichert
steve Phone #: ###-#### corr made, ric ok
Electrical Rough-In8/1/20078/1/20078/1/2007PFAIL
DetailsBob Reichert
Contact Steve Berry with any problems or questions on the Rough in. Thank you and have a great day.
Phone #: ###-#### Internet Inspection Request from: Laura Longshaw called, left message, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A)(1) recpts shall be installed such that no point along wall space is over 6' from an outlet, 314.20 in walls of combustible material, box shall be flush with finished surface
Application received  8/1/2007  
Issue permit  8/1/2007 DONE