Permit Information
Permit NumberELE07-02961
StatusFinaled
Name JOHN REESE
Site Address 2014 S OWYHEE AVE
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/26/20101/26/20101/26/2010PPASS
DetailsBob Reichert
John Phone #: ###-#### ok to final, owner moved in, checked available receptacles only, no esc this project
ELE-Aging Inspection12/1/200912/1/200912/4/2009 DONE
DetailsBob Reichert
no activity
Electrical Rough-In9/29/20099/29/20099/29/2009PPASS
DetailsBob Reichert
john Phone #: ###-#### corrections made, ric ok, no esc this project
Electrical Rough-In9/28/20099/28/20099/28/2009PFAIL
DetailsBob Reichert
corrections not all made, created others, will call back after install new box for broken cable clamp, use looms for wiring support, lengthen short ground wires, add securing for wires within 8" of box, no esc this project
Electrical Rough-In9/24/20099/25/20099/25/2009AFAIL
DetailsJack Frank
john Phone #: ###-#### met owner corr. 410.2&16 clearence for closet fixtures, 210.52(A) outlet spacing, fixed panel of sider, recepts not allowed above baseboard heaters, 210.52(F)&210.11(C)(2)all recept outlets in laundry rm shall be 20 amp laundry circuit, 314,16 box fill everywhere 314.43 screws not alled in non-metallic boxes, 300.14 shall provide 6" free length conductor note some of the violations posted are the same ones noted on prior inspection back in 2008
Electrical Rough-In9/24/20099/24/20099/24/2009PNR
DetailsBob Reichert
John Phone #: ###-#### thought we would be there after 3, still had to do hall, closet and laundry room, told to recall when done, no esc this project
Electrical Rough-In3/6/20093/6/20093/6/2009PPASS
DetailsBob Reichert
John Phone #: ###-####ric ok for kitchen, bedroom, downstairs utilities anop, no esc this project
Electrical Rough-In3/5/20093/6/20093/6/2009ANR
DetailsBob Reichert
John Phone #: ###-#### met owner, told that he must be done before he calls for inspection, no esc this project
Electrical Rough-In9/25/20089/25/20089/25/2008PPART
DetailsBob Reichert
john Phone #: ###-#### corrections made, ok to cover dining room only, owner made layout, signed plan also, no esc this project
Electrical Rough-In8/28/20088/28/20088/28/2008PFAIL
DetailsJack Frank
John Phone #: ###-#### mey owner job not ready and violations makeup, shall address small appliance branch circuits, no screws in plastic boxes, nail plates and 11/4" outside recept install all boxes dinning rm
Electrical Rough-In6/2/20086/2/20086/2/2008PPART
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/2/2008 at 8:09:50 AM. Contact: ###-####. living room and front bath only ok to cover, no wiring in ceiling on south side if covered next trip, no esc
Electrical Rough-In4/17/20084/17/20084/17/2008PNR
DetailsBob Reichert
john Phone #: ###-#### met owner, explained make-up had to be done and 1 1/4" shall be provided for for nm cable, shall staple nm within 8" of boxes
Conference10/8/200710/8/200710/8/2007PDONE
DetailsBob Reichert
john Phone #: ###-#### talked about upgrade roof and getting rid old knob and tube, bringing open areas up to code, when to call for ri inspection
Application received  8/24/2007  
Issue PAID IN FULL permit  8/24/2007 DONE