Final | 10/29/2007 | 10/30/2007 | 10/30/2007 | A | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 10/29/2007 at 3:46:18 PM. Contact: ###-####. ok final
|
Permanent Service | 10/4/2007 | 10/4/2007 | 10/4/2007 | P | CANC |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:17 AM. Contact: ###-####. see add r/i
|
Electrical Rough-In | 10/4/2007 | 10/4/2007 | 10/4/2007 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:17 AM. Contact: ###-####. u/g from house to garage ok
|
Electrical Rough-In | 9/7/2007 | 9/7/2007 | 9/7/2007 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 9/7/2007 at 8:44:38 AM. Contact: ###-####. corrections made, ric ok Note: no underground house to garage inspected
|
Electrical Rough-In | 9/6/2007 | 9/6/2007 | 9/6/2007 | P | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 9/6/2007 at 10:33:31 AM. Contact: ###-####. called contr, corrections not made, fee due, crossed off what was fixed on corr notice
|
Reinspection Fee (no hold) | 9/6/2007 | 9/6/2007 | 9/6/2007 | P | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 9/6/2007 at 10:33:31 AM. Contact: ###-####. see ri comments
|
Electrical Rough-In | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | FAIL |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James called nec 312.5 all conductors entering enclosures shall have abrasion protection, 314.20 boxes shall be flush with finished surface in walls of combustible material, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from face of framing members, 210.52(A)(1)&(2) 2' walls shall have recpt installed, recpt shall be within 6' of entry,210.53 (A) recpt shall be installed at rear of dwelling, BCC all u/g shall be inspected before cover, address shall be posted
|
Rough-In Permanent Service | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | CANC |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James see ri and p/s
|
Permanent Service | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | PASS |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James p/s u/g n ok
|
Application received | | | 9/5/2007 | | |
|
|
|
|
Issue permit | | | 9/5/2007 | | DONE |
|
|
|
|