Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE07-03083
StatusFinaled
Name BICANDI ELECTRIC LLC
Site Address 1920 S GOURLEY ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/29/200710/30/200710/30/2007APASS
DetailsMike Kinnear
Scheduled by a contractor via Hello! on 10/29/2007 at 3:46:18 PM. Contact: ###-####. ok final
Permanent Service10/4/200710/4/200710/4/2007PCANC
DetailsJack Frank
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:17 AM. Contact: ###-####. see add r/i
Electrical Rough-In10/4/200710/4/200710/4/2007PPASS
DetailsJack Frank
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:17 AM. Contact: ###-####. u/g from house to garage ok
Electrical Rough-In9/7/20079/7/20079/7/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/7/2007 at 8:44:38 AM. Contact: ###-####. corrections made, ric ok Note: no underground house to garage inspected
Electrical Rough-In9/6/20079/6/20079/6/2007PFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/6/2007 at 10:33:31 AM. Contact: ###-####. called contr, corrections not made, fee due, crossed off what was fixed on corr notice
Reinspection Fee (no hold)9/6/20079/6/20079/6/2007PFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/6/2007 at 10:33:31 AM. Contact: ###-####. see ri comments
Electrical Rough-In9/5/20079/5/20079/5/2007PFAIL
DetailsBob Reichert
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James called nec 312.5 all conductors entering enclosures shall have abrasion protection, 314.20 boxes shall be flush with finished surface in walls of combustible material, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from face of framing members, 210.52(A)(1)&(2) 2' walls shall have recpt installed, recpt shall be within 6' of entry,210.53 (A) recpt shall be installed at rear of dwelling, BCC all u/g shall be inspected before cover, address shall be posted
Rough-In Permanent Service9/5/20079/5/20079/5/2007PCANC
DetailsBob Reichert
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James see ri and p/s
Permanent Service9/5/20079/5/20079/5/2007PPASS
DetailsBob Reichert
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James p/s u/g n ok
Application received  9/5/2007  
Issue permit  9/5/2007 DONE