Permit Information
Permit NumberELE07-03085
StatusFinaled
Name BICANDI ELECTRIC LLC
Site Address 1928 S GOURLEY ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/29/200710/30/200710/30/2007APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 10/29/2007 at 3:47:57 PM. Contact: ###-####. ok to final, called contractor
Electrical Rough-In10/4/200710/4/200710/4/2007PPASS
DetailsJack Frank
Scheduled by a contractor via Hello! on 10/4/2007 at 10:20:33 AM. Contact: ###-####. u/g house to garage ok
Permanent Service10/4/200710/4/200710/4/2007PCANC
DetailsJack Frank
Scheduled by a contractor via Hello! on 10/4/2007 at 10:20:33 AM. Contact: ###-####. see added r/i
Electrical Rough-In9/7/20079/7/20079/7/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/7/2007 at 8:46:30 AM. Contact: ###-####. corrections made, ric ok, Note: no inspection made from house to garage for u/g
Electrical Rough-In9/6/20079/6/20079/6/2007PFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/6/2007 at 10:36:34 AM. Contact: ###-####. called contr, corrections not all made, crossed off what was fixed on corr notice, fee due
Reinspection Fee (no hold)9/6/20079/6/20079/6/2007PFAIL
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/6/2007 at 10:36:34 AM. Contact: ###-####. see ri
Permanent Service9/6/20079/6/20079/6/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/6/2007 at 10:36:34 AM. Contact: ###-####. p/s u/g n ok
Rough-In Permanent Service9/5/20079/5/20079/5/2007PFAIL
DetailsBob Reichert
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James called ,NEC 110.26(a) work space shall be provided about equipment- no low voltage below panel, 312.5 shall provide abrasion protection for all conductors entering enclosures, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush with finished surface in walls of combustible materials, 210.52(A)(2) shall provide recpts in 2' walls, 334.30 flat nm cable shall not be stapled on edge, 314.17(C) nm cable shall be stapled within 8" of box, BCC all underground shall be inspected before cover, address shall be posted
Application received  9/5/2007  
Issue permit  9/5/2007 DONE