Second Notice ELE | 7/30/2008 | 7/30/2008 | 12/29/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | 7/10/2008 | 7/10/2008 | 7/30/2008 | | DONE |
Mike Kinnear
|
|
|
|
Final | 7/10/2008 | 7/10/2008 | 7/10/2008 | P | PASS |
Mike Kinnear
|
|
|
Matt Phone #: ###-#### ok final note esc permit on hold
|
Final | 7/9/2008 | 7/9/2008 | 7/9/2008 | P | PART |
Mike Kinnear
|
|
|
Matt Phone #: ###-#### all inside work completed just needs outside conduit inspection note parcel hold on esc permit
|
Final | 7/2/2008 | 7/2/2008 | 7/2/2008 | P | PART |
Mike Kinnear
|
|
|
Matt Phone #: ###-#### ok temp. occ.ok signed card. welders, panel labling, & outside conduit run for parking lot lights.
|
Electrical Rough-In | 6/4/2008 | 6/4/2008 | 6/4/2008 | P | PASS |
Mike Kinnear
|
|
|
Matt Phone #: ###-#### ok cover back offices ceiling only note hold on esc permit unable to add inspection
|
Electrical Rough-In | 6/3/2008 | 6/4/2008 | 6/4/2008 | A | NR |
Mike Kinnear
|
|
|
Mat; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt t/w mat they resched for this afternoon inspection
|
Override - Parcel Holds | 6/4/2008 | 1/1/1900 | 6/4/2008 | | |
|
|
|
OK per Rita
|
Electrical Rough-In | 5/30/2008 | 5/30/2008 | 5/30/2008 | P | PASS |
William E Thomas
|
|
|
matt - ###-#### - ceiling cover - as early as possible . .1. ok to cover cieling. . .
|
Override - Parcel Holds | | | 5/30/2008 | | |
|
|
|
|
Electrical Rough-In | 5/27/2008 | 5/28/2008 | 5/28/2008 | A | NR |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 5/27/2008 at 12:32:02 PM. Contact: ###-####. nec300.11(A)(2) id wires, make needs to be completed, & all wires off ceiling grid
|
Conference | 4/25/2008 | 4/25/2008 | 4/25/2008 | P | DONE |
Jack Frank
|
|
|
talked with engneer and contr, 240.21(C) (3) shall provide conductors from X former secondary taps rated for 725 amps or prvide main breaker ahead of 120/208 panel
|
Conference | 4/24/2008 | 4/24/2008 | 4/24/2008 | P | DONE |
Jack Frank
|
|
|
met with journeyman and talked with Skip the owner ok ELE contr about overcurrent protection required for secondary side of Xformer
|
Permanent Service | 4/23/2008 | 4/23/2008 | 4/23/2008 | P | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 4/23/2008 at 6:57:30 AM. Contact: ###-####. p/s u/g n ok note correction on secondary side of transformer NEC240.21(B)(2)(2) secondary conductors shall terminal in the proper size brker or fuses. & grounding properly done
|
Electrical Rough-In | 4/21/2008 | 4/21/2008 | 4/21/2008 | P | PASS |
William E Thomas
|
|
|
Scheduled by a contractor via Hello! on 4/21/2008 at 10:00:11 AM. Contact: ###-####. . .1. ri ok. . .
|
Electrical Rough-In | 4/9/2008 | 4/10/2008 | 4/10/2008 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 4/9/2008 at 4:24:21 PM. Contact: ###-####. ok cover walls & hard lid ceilings expect second floor stair area & east side of building
|
Electrical Rough-In | 4/7/2008 | 4/8/2008 | 4/8/2008 | A | PART |
Pat Lass
|
|
|
matt Phone #: ###-#### firsr floor parts room walls ok
|
Electrical Rough-In | 11/9/2007 | 11/13/2007 | 11/13/2007 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 11/9/2007 at 3:20:33 PM. Contact: ###-####. ok cover under slab conduit north east side only
|
Temporary Service | 11/9/2007 | 11/13/2007 | 11/13/2007 | A | CANC |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 11/9/2007 at 3:19:37 PM. Contact: ###-####.
|
Electrical Rough-In | 11/7/2007 | 11/8/2007 | 11/8/2007 | A | PASS |
Mike Kinnear
|
|
|
underground--for temp job shack--gib; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok cover underground conduit for temp job shack
|
Electrical Rough-In | 10/30/2007 | 10/31/2007 | 10/31/2007 | A | PART |
Mike Kinnear
|
|
|
skip Note: cover up for trench Phone #: ###-#### ok cover under ground conduit feeders from transformer & 4inch & 1inch southeast corner parking lot
|
Electrical Rough-In | 10/25/2007 | 10/26/2007 | 10/26/2007 | A | PART |
Bob Reichert
|
|
|
matt - underground Phone #: ###-#### called contractor, ok to cover 3/4" conduit in center areas only, still needs spacers for service conduit, will leave open, told contractor 2" going out to parking lot lighting out west side building had to be lowered to 2' deep, no plans to sign yet
|
Electrical Rough-In | 10/23/2007 | 10/24/2007 | 10/24/2007 | A | PART |
Mike Kinnear
|
|
|
matt Note: underground Phone #: ###-#### ok cover conduit feeders from service to middle of building
|
Electrical Rough-In | 10/22/2007 | 10/23/2007 | 10/23/2007 | A | PART |
Mike Kinnear
|
|
|
justin Note: under/conduit inspect Phone #: ###-#### conf need to see under ground feeders (pot hole) need to uncover service conduits & comply with nec310.15 duct bank requirements
|
Issue permit | | | 9/24/2007 | | DONE |
|
|
|
|
Application received | | | 9/24/2007 | | |
|
|
|
|
Electrical Rough-In | 9/24/2007 | 9/25/2007 | | A | |
|
|
|
Upher ground inpsection please Justin ###-####
|