Final | 12/10/2007 | 12/10/2007 | 12/10/2007 | P | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence ok
|
Final | 12/6/2007 | 12/7/2007 | 12/7/2007 | P | FAIL |
Jack Frank
|
|
|
Electrical final Phone #: ###-#### Internet Inspection Request from: Tim Lawrence corr. called left message, 410.8 enclosed fixture requied in MB closet 408.4 be specific purpose and use
|
Reinspection Fee (no hold) | 12/7/2007 | 12/7/2007 | 12/7/2007 | P | DONE |
Jack Frank
|
|
|
Electrical final Phone #: ###-#### Internet Inspection Request from: Tim Lawrence fee due corr posted
|
Rough-In Permanent Service | 11/4/2007 | 11/5/2007 | 11/5/2007 | P | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence corr. made r/i p/s u/g new ok
|
Rough-In Permanent Service | 11/1/2007 | 11/2/2007 | 11/2/2007 | P | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence correction not made called explained again requirements for nail plates
|
Rough-In Permanent Service | 10/31/2007 | 11/1/2007 | 11/1/2007 | P | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence corr fee due called left message, 300.4 (A)(1) nail plates inside outside edges, BCC complete makeup, 314,43 no screws allowed in plastic boxes
|
Reinspection Fee (no hold) | 11/1/2007 | 11/1/2007 | 11/1/2007 | P | DONE |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence fee due violations not corrected,new ones created
|
Electrical Rough-In | 10/30/2007 | 10/31/2007 | 10/31/2007 | P | FAIL |
Jack Frank
|
|
|
Contact - Tim @ Leading Edge Electric Electrical Rough Rewire on Existing home Phone #: ###-#### Internet Inspection Request from: Tim Lawrence called corr. 300.4 nail plates, 210.52(A&C1), outlet spacing NE bed rm and countertops kitchen, 314.20 outside boxes shall be flush with siding, range hood outlet ?, complete all makeup
|
Application received | | | 10/30/2007 | | DONE |
|
|
|
This permit was created on the web by Tim Lawrence
|