Final | 12/10/2007 | 12/11/2007 | 12/11/2007 | A | PASS |
Jack Frank
|
|
|
Nancy; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
Electrical Rough-In | 12/4/2007 | 12/4/2007 | 12/4/2007 | P | PASS |
Bob Reichert
|
|
|
nancy Phone #: ###-#### corrections made, ric ok
|
Electrical Rough-In | 12/3/2007 | 12/4/2007 | 12/4/2007 | A | FAIL |
Bob Reichert
|
|
|
nancy Phone #: ###-#### met owner, told correction nec 300.14 shall provide 6" free conductor length at each box
|
Conference | 11/26/2007 | 11/27/2007 | 11/27/2007 | A | DONE |
Bob Reichert
|
|
|
nancy-- ###-####- met owner, they are doing some remodel work in existing house, told to have inspection before cover, 1 1/4" holes and cable, stapling, circuits, box fill, told if walls open, need to use new work boxes, not cut-in boxes
|
Application received | | | 11/26/2007 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 11/26/2007 | | DONE |
|
|
|
|