Final | 2/15/2008 | 2/15/2008 | 2/15/2008 | A | PASS |
Bob Reichert
|
|
|
please re-inspect correction Phone #: ###-#### Internet Inspection Request from: gary batten corrections made, ok to final
|
Final | 2/8/2008 | 2/8/2008 | 2/8/2008 | P | FAIL |
Bob Reichert
|
|
|
please final Phone #: ###-#### Internet Inspection Request from: gary batten called, left correction notice, NEC 348.30(A) fmc shall be securely fastened within 12" of cabinet, 210.12(B) bedrooms shall be protected by afci that supply all outlets (including lights)
|
Final | 2/7/2008 | 2/8/2008 | 2/8/2008 | A | NH |
Jack Frank
|
|
|
Please final Phone #: ###-#### Internet Inspection Request from: gary batten ok notice posted
|
Reinspection Fee (no hold) | 2/8/2008 | 2/8/2008 | 2/8/2008 | A | DONE |
Jack Frank
|
|
|
Please final Phone #: ###-#### Internet Inspection Request from: gary batten fee due no access
|
Final | 2/5/2008 | 2/5/2008 | 2/5/2008 | P | CANC |
Bob Reichert
|
|
|
please final , electrician is john fivecoat Phone #: ###-#### Internet Inspection Request from: gary batten Inspection cancelled from web by: gary batten
|
Electrical Rough-In | 1/9/2008 | 1/10/2008 | 1/10/2008 | A | PASS |
Bob Reichert
|
|
|
John Fivecoat is the electrician @###-####, please provide rough in inspection Phone #: ###-#### Internet Inspection Request from: gary batten ric ok basement area only
|
Application received | | | 1/2/2008 | | DONE |
|
|
|
This permit was created on the web by gary batten
|